Evaluation of mitral chordae tendineae length using four-dimensional computed tomography

Author:

Mori Takuya,Matsushita Satoshi,Morita Terumasa,Abudurezake Abulaiti,Mochizuki Junji,Amano Atsushi

Abstract

BACKGROUND Mitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation. Achieving precise measurements of artificial chordae tendineae length (CL) is an important factor in the procedure; however, no objective index currently exists to facilitate this measurement. Therefore, preoperative assessment of CL is critical for surgical planning and support. Four-dimensional x-ray micro-computed tomography (4D-CT) may be useful for accurate CL measurement considering that it allows for dynamic three-dimensional (3D) evaluation compared to that with transthoracic echocardiography, a conventional inspection method. AIM To investigate the behavior and length of mitral chordae tendineae during systole using 4D-CT. METHODS Eleven adults aged > 70 years without mitral valve disease were evaluated. A 64-slice CT scanner was used to capture 20 phases in the cardiac cycle in electrocardiographic synchronization. The length of the primary chordae tendineae was measured from early systole to early diastole using the 3D image. The primary chordae tendineae originating from the anterior papillary muscle and attached to the A1-2 region and those from the posterior papillary muscle and attached to the A2-3 region were designated as cA and cP, respectively. The behavior and maximum lengths [cA (ma), cP (max)] were compared, and the correlation with body surface area (BSA) was evaluated. RESULTS In all cases, the mitral anterior leaflet chordae tendineae could be measured. In most cases, the cA and cP chordae tendineae could be measured visually. The mean cA (max) and cP (max) were 20.2 mm ± 1.95 mm and 23.5 mm ± 4.06 mm, respectively. cP (max) was significantly longer. The correlation coefficients (r) with BSA were 0.60 and 0.78 for cA (max) and cP (max), respectively. Both cA and cP exhibited constant variation in CL during systole, with a maximum 1.16-fold increase in cA and a 1.23-fold increase in cP from early to mid-systole. For cP, CL reached a plateau at 15% and remained elongated until end-systole, whereas for cA, after peaking at 15%, CL shortened slightly and then moved toward its peak again as end-systole approached. CONCLUSION The study suggests that 4D-CT is a valuable tool for accurate measurement of both the length and behavior of chordae tendineae within the anterior leaflet of the mitral valve.

Publisher

Baishideng Publishing Group Inc.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3