Time-varying regularity of changes in biomechanical properties of the corneas after removal of anterior corneal tissue

Author:

Zhang Di,Qin Xiao,Zhang Haixia,Li LinORCID

Abstract

Abstract Background The corneal biomechanical properties with the prolongation of time after corneal refractive surgery are important for providing a mechanical basis for the occurrence of clinical phenomena such as iatrogenic keratectasia and refractive regression. The aim of this study was to explore the changes of corneal elastic modulus, and stress relaxation properties from the 6-month follow-up observations of rabbits after a removal of anterior corneal tissue in simulation to corneal refractive surgery. Methods The anterior corneal tissue, 6 mm in diameter and 30–50% of the original corneal thickness, the left eye of the rabbit was removed, and the right eye was kept as the control. The rabbits were normally raised and nursed for 6 months, during which corneal morphology data, and both of corneal hysteresis (CH) and corneal resistance factor (CRF) were gathered. Uniaxial tensile tests of corneal strips were performed at months 1, 3, and 6 from 7 animals, and corneal collagen fibrils were observed at months 1, 3, and 6 from 1 rabbit, respectively. Results Compared with the control group, there were statistical differences in the curvature radius at week 2 and month 3, and both CH and CRF at months 1, 2, and 6 in experiment group; there were statistical differences in elastic modulus at 1, 3, and month 6, and stress relaxation degree at month 3 in experiment group. The differences in corneal elastic modulus, stress relaxation degree and the total number of collagen fibrils between experiment and control groups varied gradually with time, and showed significant changes at the 3rd month after the treatment. Conclusions Corneas after a removal of anterior corneal tissue undergo dynamic changes in corneal morphology and biomechanical properties. The first 3 months after treatment could be a critical period. The variation of corneal biomechanical properties is worth considering in predicting corneal deformation after a removal of anterior corneal tissue.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3