New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics

Author:

Yoo Seong Ki,Shin Ki Young,Lee Tae Bum,Jin Seung Oh

Abstract

Abstract In traditional Chinese and Korean medicine, doctors first observe a patient’s pulse by gently and strongly pressing their fingers onto the wrist, and then make a diagnosis based on the observed pulse waves. The most common method to implement this diagnostic technique is to mechanically extract the pulse waves by applying a fixed range of pressures for all patients. However, this method does not consider the patients individual characteristics such as age, sex, and skin thickness. In the present study, we propose a new method of pulse wave extraction that incorporates the personal characteristics of the patients. This method measures the pulse wave signal at varying hold-down pressures, rather than applying a fixed hold-down pressure for all patients. To compare this new technique with existing methods, we extracted pulse waves from 20 subjects, and then determined the actual applied pressure at each step, the coefficient of floating and sinking pulse (CFS), and the distinction of floating/sinking pulse for each group. Consequently, each subject had a different pressure range in our proposed method, whereas all subjects had a similar pressure range in the existing method. Four of 20 subjects exhibited different floating/sinking pulse patterns due to the value of the first pressure step and the range of hold-down pressures. These four subjects were categorized as overweight based on BMI. In addition, the moving distance of the proposed method was longer than the existing method (p = 0.003, paired t-test), and the correlation coefficient between CFS values of two different methods was 0.321, indicating that there was no correlation.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference16 articles.

1. Barker DE: Skin Thickness in the Human. Plastic & Reconstructive Surgery 1951, 7: 115-116. 10.1097/00006534-195102000-00004

2. Fu SE, Lai SP: A system for pulse measurement and analysis of Chinese medicine. In Processing of the 11th annual International Conference of the IEEE EMBS. Seattle, WA, USA: The IEEE Engineering in Medicine & Biology Society (EMBS); 1989:1695-1696. November 1989

3. Jeon YJ, Lee J, Lee YJ, Woo YJ, Ryu HH, Kim JY: Design of multi-array pulse diagnosis sensor with FDB process. The Korean Institute of Electrical Engineers, Conference on Information and Control Systems. Korea: The Korean Institute of Electrical Engineers (KIEE); 2008:367-638. Oct 2008

4. Kim KC, Kang HJ: Pulsation Biomedical Research Methodology. Korea: Daeyo-medi; 2008.

5. Kim JU, Shin SH: Development of Pulse Diagnosis Algorithm. Journal of the IEEK 2010, 37: 32-41.

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献