Abstract
Abstract
Background
Panoramic radiography is an imaging method for displaying maxillary and mandibular teeth together with their supporting structures. Panoramic radiography is frequently used in dental imaging due to its relatively low radiation dose, short imaging time, and low burden to the patient. We verified the diagnostic performance of an artificial intelligence (AI) system based on a deep convolutional neural network method to detect and number teeth on panoramic radiographs.
Methods
The data set included 2482 anonymized panoramic radiographs from adults from the archive of Eskisehir Osmangazi University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology. A Faster R-CNN Inception v2 model was used to develop an AI algorithm (CranioCatch, Eskisehir, Turkey) to automatically detect and number teeth on panoramic radiographs. Human observation and AI methods were compared on a test data set consisting of 249 panoramic radiographs. True positive, false positive, and false negative rates were calculated for each quadrant of the jaws. The sensitivity, precision, and F-measure values were estimated using a confusion matrix.
Results
The total numbers of true positive, false positive, and false negative results were 6940, 250, and 320 for all quadrants, respectively. Consequently, the estimated sensitivity, precision, and F-measure were 0.9559, 0.9652, and 0.9606, respectively.
Conclusions
The deep convolutional neural network system was successful in detecting and numbering teeth. Clinicians can use AI systems to detect and number teeth on panoramic radiographs, which may eventually replace evaluation by human observers and support decision making.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging
Cited by
47 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献