Abstract
Abstract
Background
The purpose of this study was to develop a software tool and evaluate different T1 map calculation methods in terms of computation time in cardiac magnetic resonance imaging.
Methods
The modified Look-Locker inversion recovery (MOLLI) sequence was used to acquire multiple inversion time (TI) images for pre- and post-contrast T1 mapping. The T1 map calculation involved pixel-wise curve fitting based on the T1 relaxation model. A variety of methods were evaluated using data from 30 subjects for computational efficiency: MRmap, python Levenberg–Marquardt (LM), python reduced-dimension (RD) non-linear least square, C++ single- and multi-core LM, and C++ single- and multi-core RD.
Results
Median (interquartile range) computation time was 126 s (98–141) for the publicly available software MRmap, 261 s (249–282) for python LM, 77 s (74–80) for python RD, 3.4 s (3.1–3.6) for C++ multi-core LM, and 1.9 s (1.9–2.0) for C++ multi-core RD. The fastest C++ multi-core RD and the publicly available MRmap showed good agreement of myocardial T1 values, resulting in 95% Bland–Altman limits of agreement of (− 0.83 to 0.58 ms) and (− 6.57 to 7.36 ms) with mean differences of − 0.13 ms and 0.39 ms, for the pre- and post-contrast, respectively.
Conclusion
The C++ multi-core RD was the fastest method on a regular eight-core personal computer for pre- or post-contrast T1 map calculation. The presented software tool (fT1fit) facilitated rapid T1 map and extracellular volume fraction map calculations.
Funder
National Research Foundation of Korea
DongKook Life Science
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献