Affiliation:
1. Division of Digital Healthcare, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju 26493, Republic of Korea
Abstract
Quantitative analysis of intracranial vessel segments typically requires the identification of the vessels’ centerlines, and a path-finding algorithm can be used to automatically detect vessel segments’ centerlines. This study compared the performance of path-finding algorithms for vessel labeling. Three-dimensional (3D) time-of-flight magnetic resonance angiography (MRA) images from the publicly available dataset were considered for this study. After manual annotations of the endpoints of each vessel segment, three path-finding methods were compared: (Method 1) depth-first search algorithm, (Method 2) Dijkstra’s algorithm, and (Method 3) A* algorithm. The rate of correctly found paths was quantified and compared among the three methods in each segment of the circle of Willis arteries. In the analysis of 840 vessel segments, Method 2 showed the highest accuracy (97.1%) of correctly found paths, while Method 1 and 3 showed an accuracy of 83.5% and 96.1%, respectively. The AComm artery was highly inaccurately identified in Method 1, with an accuracy of 43.2%. Incorrect paths by Method 2 were noted in the R-ICA, L-ICA, and R-PCA-P1 segments. The Dijkstra and A* algorithms showed similar accuracy in path-finding, and they were comparable in the speed of path-finding in the circle of Willis arterial segments.
Funder
National Research Foundation of Korea
Subject
Radiology, Nuclear Medicine and imaging
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献