Pulmonary lesions: correlative study of dynamic triple-phase enhanced CT perfusion imaging with tumor angiogenesis and vascular endothelial growth factor expression

Author:

Zou Mingyue,Zhao Zhenhua,Zhang Bingqian,Mao Haijia,Huang Yanan,Wang Cheng

Abstract

Abstract Background To investigate value of the quantitative perfusion parameters of dynamic triple-phase enhanced CT in differential diagnosis of pulmonary lesions, and explore the correlation between perfusion parameters of lung cancer with microvessel density (MVD) and vascular endothelial growth factor (VEGF). Methods 73 consecutive patients with lung lesions who successfully underwent pre-operative CT perfusion examination with dynamic triple-phase enhanced CT and received a final diagnosis by postoperative pathology or a clinical follow-up. The cases were divided into malignant and benign groups according to the pathological results. CT perfusion parameters, such as Median, Mean, Standard deviation (Std), Q10, Q25, Q50, Q75, Q90 of pulmonary artery perfusion (PAP), bronchial artery perfusion (BAP), perfusion index (PI) and arterial enhancement fraction (AEF) were obtained by performing computed tomography perfusion imaging (CTPI). Computed tomography perfusion (CTP) parameters were compared between malignant and benign lesions. The receiver operating characteristic (ROC) curve was used to assess the diagnostic efficiency of CTP parameters in diagnosing malignant lesions. The correlations between CTP parameters with MVD and VEGF were analysed in 36 lung cancer patients who had extra sections be used for immunohistochemistry staining of CD34 and VEGF. Results BAP (Mean, Std, Q90) and PI Std of benign lesions were higher than malignant lesions (p < 0.05), and PAP (Q10, Q25), PI (Median, Mean, Q10, Q25, Q50) of malignant lesions were higher than the benign (p < 0.05). The area under the ROC curve of PI Mean, PI Q10 and PI Std was 0.722 (95% CI = [0.595–0.845]), 0.728 (95% CI = [0.612–0.844]) and 0.717 (95% CI = [0.598–0.835]) respectively. Partial perfusion parameters of BAP and AEF Q10 were positively correlated with MVD (p value range is < 0.001–0.037, ρ value range is 0.483–0.683), and partial perfusion parameters of PI were negatively correlated with MVD (p value range is 0.001–0.041,ρvalue range is − 0.523–− 0.343). Partial perfusion parameters of BAP and AEF Q10 were positively correlated with VEGF (p value range is 0.001–0.016, ρvalue range is 0.398–0.570), meanwhile some perfusion parameters of PAP and PI were negatively correlated with VEGF (p value range is 0.001–0.040, ρ value range is − 0.657–0.343). Conclusions Quantitative parameters of dynamic triple-phase enhanced CT can provide diagnostic basis for the differentiation of lung lesions, and there were connection with tumor angiogenesis and vascular endothelial growth factor expression.

Funder

Key Laboratory of Functional Molecular Imaging of Tumor and Interventional Diagnosis and Treatment of Shaoxing City, Shaoxing People’s Hospital

Medicine and Health Science and Technology Plan Project in Zhejiang Province of China

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3