Abstract

Abstract Introduction A novel fully porous acetabular titanium shell has been designed to reduce stiffness mismatch between bone and implant and promote osseointegration in complex (cTHA) and revision total hip arthroplasty (rTHA). A highly cross-linked polyethylene (XLPE) liner is cemented within the cup to reduce wear rates and increase survivorship. This study reported the outcomes of an XLPE liner cemented into a novel 3D-printed fully porous cup in cTHA and rTHA. Methods Presented was a multicenter retrospective review of 40 patients (6 cTHA and 34 rTHA) who underwent THA with a fully porous titanium acetabular cup and cemented XLPE liner. Data were collected on demographics, surgical information, outcomes, including osseointegration and migration and implant survivorship. Results On average, patients were 71.42 ± 9.97 years old and obese (BMI: 30.36 ± 6.88 kg/m2) and were followed up for a mean time of 2.21 ± 0.77 years. Six patients underwent cTHA and 34 patients underwent rTHA. The mean hospital length of stay was 5.34 ± 3.34 days. Three (7.5%) 90-day readmissions were noted. Harris Hip Scores improved, on average, from 53.87 ± 12.58 preoperatively to 83.53 ± 12.15 postoperatively (P<0.001). One case of acetabular shell aspetic loosening with migration was noted. Thirty-nine of the 40 acetabular components were fully osseointegrated without migration. Two patients underwent re-revision surgery for PJI and one patient received acetabular shell+liner re-revision due to aseptic loosening. Kaplan-Meier analysis showed an all-cause revision-free survival rate of 95.0% at 6 months and 1 year, and 92.0% at 4-years. Aseptic acetabular cup, liner dislocation/loosening, and fracture-free survival was 100% at 6 months and 1-year, and 97.1% at 2 years. Conclusion The combined use of a novel 3D-printed fully porous titanium acetabular shell and cemented XLPE acetabular liner yielded excellent rates of osseointegration, and all-cause and acetabular aseptic loosening survivorship at a minimum 1-year follow-up. Further long-term studies are needed to assess the longevity of this construct.

Funder

Smith&Nephew

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3