Affiliation:
1. Clemson—Medical University of South Carolina Bioengineering Program, Department of Bioengineering, Clemson University, Charleston, SC 29464, USA
Abstract
Additive manufacturing (AM) of orthopedic implants has increased in recent years, providing benefits to surgeons, patients, and implant companies. Both traditional and new titanium alloys are under consideration for AM-manufactured implants. However, concerns remain about their wear and corrosion (tribocorrosion) performance. In this study, the effects of fretting corrosion were investigated on AM Ti-29Nb-21Zr (pre-alloyed and admixed) and AM Ti-6Al-4V with 1% nano yttria-stabilized zirconia (nYSZ). Low cycle (100 cycles, 3 Hz, 100 mN) fretting and fretting corrosion (potentiostatic, 0 V vs. Ag/AgCl) methods were used to compare these AM alloys to traditionally manufactured AM Ti-6Al-4V. Alloy and admixture surfaces were subjected to (1) fretting in the air (i.e., small-scale reciprocal sliding) and (2) fretting corrosion in phosphate-buffered saline (PBS) using a single diamond asperity (17 µm radius). Wear track depth measurements, fretting currents and scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) analysis of oxide debris revealed that pre-alloyed AM Ti-29Nb-21Zr generally had greater wear depths after 100 cycles (4.67 +/− 0.55 µm dry and 5.78 +/− 0.83 µm in solution) and higher fretting currents (0.58 +/− 0.07 µA). A correlation (R2 = 0.67) was found between wear depth and the average fretting currents with different alloys located in different regions of the relationship. No statistically significant differences were observed in wear depth between in-air and in-PBS tests. However, significantly higher amounts of oxygen (measured by oxygen weight % by EDS analysis of the debris) were embedded within the wear track for tests performed in PBS compared to air for all samples except the ad-mixed Ti-29Nb-21Zr (p = 0.21). For traditional and AM Ti-6Al-4V, the wear track depths (dry fretting: 2.90 +/− 0.32 µm vs. 2.51 +/− 0.51 μm, respectively; fretting corrosion: 2.09 +/− 0.59 μm vs. 1.16 +/− 0.79 μm, respectively) and fretting current measurements (0.37 +/− 0.05 μA vs. 0.34 +/− 0.05 μA, respectively) showed no significant differences. The dominant wear deformation process was plastic deformation followed by cyclic extrusion of plate-like wear debris at the end of the stroke, resulting in ribbon-like extruded material for all alloys. While previous work documented improved corrosion resistance of Ti-29Nb-21Zr in simulated inflammatory solutions over Ti-6Al-4V, this work does not show similar improvements in the relative fretting corrosion resistance of these alloys compared to Ti-6Al-4V.
Funder
Wyss Endowment at Clemson University
DePuy Synthes
MUSC T32 Dental Training Grant
Reference75 articles.
1. In Vitro Corrosion Testing of Titanium Surgical Implant Alloys: An Approach to Understanding Titanium Release from Implants;Solar;J. Biomed. Mater. Res.,1979
2. Textor, M., Sittig, C., Frauchiger, V., Tosatti, S., and Brunette, D.M. (2001). Titanium in Medicine, Springer.
3. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application;Pan;Electrochim. Acta,1996
4. Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide;Pan;J. Biomed. Mater. Res.,1994
5. Okazaki, Y. (2019). Characterization of oxide film of implantable metals by electrochemical impedance spectroscopy. Materials, 12.