Optical bench evaluation of the effect of pupil size in new generation monofocal intraocular lenses

Author:

Alarcon Aixa,Canovas Carmen,Koopman Bram,Pande Milind V,Koch Douglas D,Piers Patricia

Abstract

Abstract Background A new generation of enhanced monofocal IOLs has been introduced to slightly increase the depth of focus as compared to standard monofocal IOLs. The purpose of this study is to evaluate the effect of pupil size on the through-focus optical performance of three new enhanced monofocal IOLs, designed to improve the range of vision as compared to standard monofocal IOLs. Methods Optical bench testing in white light was performed for different pupils, using an average cornea eye. Distance image quality was evaluated using Modulation Transfer Function (MTF) measurements. Through-focus Visual Acuity (VA) was simulated from these measurements (sVA). Three enhanced monofocal IOLs (ICB00, ISOPure, and RayOne-EMV) and three standard monofocal IOLs: two aspheric (ZCB00 and SN60WF) and one spherical (AAB00) were included. Results The enhanced monofocal IOLs provided an improvement in the intermediate sVA as compared to standard monofocal IOLs. For ICB00, the improvement was independent of the pupil size, while for the ISOPure and RayOne-EMV, the intermediate sVA improved with increased pupil size. Similar to the spherical monofocal IOL, the ISOPure and RayOne-EMV showed a strong correlation between improvement in intermediate sVA and reduction of distance sVA and MTF, and increasing pupil size. ICB00 provided the same distance sVA as the aspheric monofocal IOLs and the lowest variability in MTF with pupil size. Conclusion Optical bench results showed that the ISOPure and RayOne-EMV provide similar performance to a spherical monofocal IOL, with a strong pupil dependency for distance and intermediate vision. The other enhanced monofocal IOL, ICB00, provided a sustained improvement in simulated intermediate VA and maintained distance image quality comparable to that of the standard aspheric monofocal IOLs, even for larger pupils.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3