Optical Behavior of an Enhanced Monofocal Intraocular Lens Compared with a Standard One

Author:

García-Montero María1,Garzón Nuria1ORCID,Gonzalez-Fernandez Veronica2ORCID,Gómez-Pedrero José Antonio2ORCID,Albarrán-Diego César3ORCID

Affiliation:

1. Departamento de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, E-28037 Madrid, Spain

2. Departamento de Óptica, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, E-28037 Madrid, Spain

3. Departamento de Óptica y Optometría y Ciencias de la Visión, Universitat de València, Doctor Moliner 50, E-46100 Burjassot, Spain

Abstract

The aim of this work was to compare an enhanced monofocal (RayOne EMV RAO200E, Rayner) and standard monofocal (RayOne RAO600C Aspheric, Rayner) intraocular lenses (IOLs) for three nominal powers (+10.00 D, +20.00 D and +30.00 D) as a function of the optical aperture diameter (pupil diameter) using a commercial Schlieren phase-shifting deflectometer NIMO TR1504 (Lambda-X, Belgium). From the wavefront maps measured by this instrument, the radial power profiles, the spherical aberration coefficients of the Zernike polynomial expansion (as a function of the optical aperture radius), and the root-mean-square (RMS) of the high-order aberrations (HOAs) were obtained and analyzed by comparing the two models. The results showed that the effective added power that could be obtained with the enhanced model depended directly on the pupil size and the power of the IOL implanted. The higher additions were achieved with the higher nominal IOL powers. The relationship between the pupil diameter, the corneal aberration of the patients and the power profile of these IOLs could have a crucial implication on the far distance and the final effective addition. However, it is important to note that these findings should be clinically validated through the implantation of these models in patients’ lenses.

Funder

Spanish State Research Agency

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3