Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions

Author:

He Tianrui,Zhu Yi,Zhou JiboORCID

Abstract

Abstract Background The current study compared optical quality before and after implantation of a posterior chamber phakic intraocular lens with a central hole [V4c implantable collamer lens (ICL)] under bright and dark lighting conditions by means of the Optical Quality Analysis System™ (OQAS; Visiometrics, Terrassa, Spain). Methods This prospective study involved 91 eyes of 46 consecutive high myopia patients (15 males and 31 females, average spherical equivalent − 10.50 ± 0.33D) undergoing implantation of a V4c ICL. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs; 100, 20, and 9%), under different lighting conditions, were measured before and 1 week, 1 month, and 3 months after surgery. Results All optical parameters showed significant improvements, at all time points, under dark condition after surgery. We observed no significant changes in PVA 9% at 1 week (mean value 0.539, P = 0.12) or 1 month after surgery (mean value 0.573, P = 0.08) under bright condition; but all other postoperative parameters improved significantly. Comparing the two lighting conditions, the OSI decreased more under dark conditions at 1 week (P = 0.02), 1 month (P = 0.004), and 3 months (P = 0.002), but there was no significant difference in any other parameter. In addition, patients were divided into super high myopia (group S, spherical equivalent greater than − 10 D) and high myopia (group H, spherical equivalent from − 6 D to − 10 D), the group S improved significantly more than group H in all parameters, under both bright and dark conditions. Conclusions V4c ICL implantation improved optical quality under both bright and dark lighting conditions, and had a better ability to reduce the extent of scattering in the dark. Furthermore, group S achieved greater improvement in visual quality, which should be considered by physicians before surgery.

Funder

The Science and Technology Commission of Shanghai

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3