Measurement of Static and Dynamic Pupillary Characteristics after Implantable Collamer Lens with a Central Hole (ICL V4c) by Sirius Anterior Segment Analysis System

Author:

Yang Jing1,Zhang Xiaodi1,Zhong Mei1,Wang Weiqun1

Affiliation:

1. Department of Ophthalmology/ the First Affiliated Hospital of Zhengzhou University/ Henan Eye Hospital/Zhengzhou/China

Abstract

Abstract Background To investigate the static and dynamic pupillometry characteristics before and after ICL V4c implantation under different light conditions. Methods This prospective study involved 210 consecutive high myopia patients undergoing implantation of a V4c ICL. Sirius anterior eye segment analysis system (CSO, Florence, Italy) was used for pupillometry preoperatively and 2 weeks, 1 month, and 3 months after surgery. Static pupillometry measurements (pupil diameter at 3 standardized illumination levels) and dynamic parameters (including initial pupil diameter, minimum pupil diameter after light stimulation, and velocity of dilation) were measured. Results Under the scotopic, mesopic and photopic conditions, PD decreased significantly after ICL implantation and restored to the preoperative level 1–3 months after surgery. Initial PD and minimum PD after light stimulation at all time points after surgery had no statistical differences, and the velocity of pupil dilation showed no significant changes at the observed time points. Under three light conditions, all pupil center coordinates shifted toward infra-temporal sites after surgery, and pupil center coordinates gradually approached cornea center after surgery. The scotopic and photopic vaults at the observed time points after ICL implantation were positively correlated with scotopic, mesopic, and photopic PD, while they were not correlated with initial pupil, minimum PD after light stimulation, the velocity of pupil dilation within 1 second, 2 seconds and 1–2 seconds after light stimulation. Conclusions ICL V4C implantation has an effect on pupil diameter in the early postoperative period, pupil diameter became smaller under the photopic, mesopic and scotopic conditions, but restored to the preoperative level about 1–3 months after surgery under the three conditions. Trial registration: The ethics committee of Zhengzhou University’s First Affiliated Hospital gave its approval to this study (2021-KY-0872-002).

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3