Investigation of predictability and influence factors of the achieved lenticule thickness in small incision lenticule extraction

Author:

Wu Fang,Yin Houfa,Chen Xinyi,Yang Yabo

Abstract

Abstract Background To evaluate the differences between the predicted and achieved lenticule thickness (ΔLT) after small incision lenticule extraction (SMILE) surgery and investigate relationships between ΔLT and predicted lenticule thickness in SMILE. Methods A total of 184 eyes from 184 consecutive patients who underwent SMILE were included in this prospective study. One eye for each patient was randomly selected and included for statistical analysis. To achieve emmetropia, nomogram adds 10% correction of spherical refractive. An ultrasound pachymetry measurement and Scheimpflug camera corneal topography were obtained before and at 3 months after SMILE. The achieved lenticule thickness was calculated by comparing the preoperative examinations with postoperative examinations using ultrasound pachymetry and Pentacam software measurements. The pupil center and corneal vertex were selected as the 2 locations for measurement calculation on Pentacam. Analysis of variance (ANOVA) was performed to compare mean pachymetry values using different instruments. Linear regression analyses were performed between the VisuMax readout lenticule thicknesses and the measured maximum corneal change, between ΔLT and predicted lenticule thickness. Results On average, the achieved lenticule thickness measured with ultrasound pachymetry was 13.02 ± 8.87 μm thinner than the predicted lenticule thickness. The proportion of ΔLT in predicted values is 11.9% (ultrasound) and about 15% (Pentacam). Linear regression analysis showed significant relationships between the predicted and each achieved lenticule thickness. Each ΔLT was significantly related to predicted lenticule thickness (ultrasound: R2 = 0.242; pupil center from Pentacam: R2 = 0.230). Conclusions An overestimation of achieved lenticule thickness was evident in this study which may exclude eligible SMILE patient. Also, our results showed that 10% increase of spherical refractive correction in the nomogram is appropriate. Furthermore, clinicians should subtract 10% of the predicted lenticule thickness to calculate the residual corneal stroma bed thickness.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Reference23 articles.

1. Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011;95(3):335–9.

2. Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: all-in-one femtosecond laser refractive surgery. J Cataract Refract Surg. 2011;37(1):127–37.

3. Dougherty PJ, Wellish KL, Maloney RK. Excimer laser ablation rate and corneal hydration. Am J Ophthalmol. 1994;118(2):169–76 Epub 1994/08/15.

4. Seiler T, Kriegerowski M, Schnoy N, Bende T. Ablation rate of human corneal epithelium and Bowman's layer with the excimer laser (193 nm). Refract Corneal Surg. 1990;6(2):99–102 Epub 1990/03/01.

5. Mrochen M, Seiler T. Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery. J Refract Surg. 2001;17(5):S584–7 Epub 2001/10/05.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3