Refractive outcomes of table-mounted and hand-held auto-refractometers in children: an observational cross-sectional study

Author:

Karabulut Müjdat,Karabulut Sinem,Karalezli Aylin

Abstract

Abstract Background To compare the refractive results of hand-held and table-mounted autorefractors. Methods We designed this study as an observational, cross-sectional study. We compared the mean spheric and cylinder power, spherical equivalent, Jackson cross-cylinder values, determined the limits of agreement (LoA), and evaluated the reliability of two autorefractors. Results We evaluated 256 eyes of 256 pediatric patients (mean age, 9.12 ± 2.26 years; range, 5–16 years). 49% of the patients were female, and 51% were male. The Nidek HandyRef-K autorefractor measured relatively more astigmatism (P < 0.001) and less hyperopia (P = 0.024). The mean differences and 95% LoA were 0.06 D ± 0.47 D (− 0.82 D to 0.98 D) in spherical power, 0.08 D ± 0.28 D (− 0.47 D to 0.64 D) in cylindrical power, 0.11 D ± 0.47 D (− 0.81 D to 1.01 D) in spherical equivalent, 0.02 D ± 0.36 D (− 0.73 D to 0.69 D) in Jackson cross-cylinder power at 0°, 0.005 D ± 0.54 D (− 1.07 D to 1.06 D) in Jackson cross-cylinder power at 45°. We found the difference within 0.50 D in 244 (95%) eyes for spherical power, in 245 (96%) eyes for cylindrical power, 228 (89%) eyes for spherical equivalent, 224 (87%) eyes for Jackson cross-cylinder power at 0°, 213 (83%) eyes for Jackson cross-cylinder power at 45°. When comparing devices, there were strong correlations for spherical power (Spearman’s rho = 0.99, P < 0.001), cylindrical power (Spearman’s rho = 0.88, P < 0.001), and spherical equivalent (Spearman’s rho = 0.98, P < 0.001). Conclusion Two autorefractors showed clinically applicable agreement limits; excellent reliability for spherical power and spherical equivalent and good reliability for cylindrical power; high positive percent agreement for spherical and cylindrical power, spherical equivalent, Jackson cross-cylinder power at 0°and 45°. These results showed that both devices might be used interchangeably for screening of refractive error in children.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3