Effect of pressures and type of ventilation on aerosol delivery to chronic obstructive pulmonary disease patients

Author:

Boules Marina E.,Laz Nabila Ibrahim,Elberry Ahmed A.,Hussein Raghda R. S.,Abdelrahim Mohamed E. A.ORCID

Abstract

Abstract Background Continuous Positive Airway Pressure (CPAP), BiPhasic Positive Airway Pressure (BiPAP), and high flow nasal cannula (HFNC) show some evidence to have efficacy in COVID-19 patients. Delivery during noninvasive mechanical ventilation (NIV) or HFNC gives faster and more enhanced clinical effects than when aerosols are given without assisted breath. The present work aimed to compare the effect of BiPhasic Positive Airway Pressure (BiPAP) mode at two different pressures; low BiPAP (Inspiratory Positive Airway Pressure (IPAP)/Expiratory Positive Airway Pressure (EPAP) of 10/5 cm water) and high BiPAP (IPAP/EPAP of 20/5 cm water), with HFNC system on pulmonary and systemic drug delivery of salbutamol. On the first day of the experiment, all patients received 2500 μg salbutamol using Aerogen Solo vibrating mesh nebulizer. Urine samples 30 min post-dose and cumulative urinary salbutamol during the next 24 h were collected on the next day. On the third day, the ex-vivo filter was inserted before the patient to collect the delivered dose to the patient of the 2500 μg salbutamol. Salbutamol was quantified using high-performance liquid chromatography (HPLC). Results Low-pressure BiPAP showed the highest amount delivered to the lung after 30 min followed by HFNC then high-pressure BiPAP. But the significant difference was only observed between low and high-pressure BiPAP modes (p = 0.012). Low-pressure BiPAP showed the highest delivered systemic delivery amount followed by HFNC then high-pressure BiPAP. Low-pressure BiPAP was significantly higher than HFNC (p = 0.017) and high-pressure BiPAP (p = 0.008). No significant difference was reported between HFNC and high-pressure BiPAP. The ex-vivo filter was the greatest in the case of low-pressure BiPAP followed by HFNC then high-pressure BiPAP. Low-pressure BiPAP was significantly higher than HFNC (p = 0.033) and high-pressure BiPAP (p = 0.008). Also, no significant difference was found between HFNC and high-pressure BiPAP. Conclusions Our results of pulmonary, systemic, and ex-vivo drug delivery were found to be consistent. The low BiPAP delivered the highest amount followed by the HFNC then the high BiPAP with the least amount. However, no significant difference was found between HFNC and high BiPAP.

Publisher

Springer Science and Business Media LLC

Subject

Pharmaceutical Science,Agricultural and Biological Sciences (miscellaneous),Medicine (miscellaneous)

Reference61 articles.

1. Harb HS, Elberry AA, Rabea H et al (2018) Performance of large spacer versus nebulizer T-piece in single-limb noninvasive ventilation. Respir Care 63(11):1360–1369

2. Labiris NR, Dolovich MB (2003) Pulmonary drug delivery. Part I: physiological factors affecting therapeutic effectiveness of aerosolized medications. Br J Clin Pharmacol 56(6):588–599

3. Larsson S, Svedmyr N (1977) Bronchodilating effect and side effects of beta2-adrenoceptor stimulants by different modes of administration (tablets, metered aerosol, and combinations thereof) a study with salbutamol in asthmatics. Am Rev Respir Dis 116(5):861–869

4. Darquenne C (2012) Aerosol deposition in health and disease. J Aerosol Med Pulm Drug Deliv 25(3):140–147

5. Duarte AG (2004) Inhaled bronchodilator administration during mechanical ventilation. Respir Care 49(6):623–634