Diagnostic accuracy and clinical applicability of the Swedish version of the 4AT assessment test for delirium detection, in a mixed patient population and setting

Author:

Johansson Yvonne A.ORCID,Tsevis Theofanis,Nasic Salmir,Gillsjö Catharina,Johansson Linda,Bogdanovic Nenad,Kenne Sarenmalm Elisabeth

Abstract

Abstract Background Delirium is common in older hospitalized patients. It has serious consequences e.g., poor health outcomes, mortality and increased costs. Despite that, many cases are undetected. Early detection of delirium is important in improving outcomes and use of assessment tools improves detection rates. The 4AT is a brief screening tool for delirium detection, which has not previously been translated into Swedish. The study aim was to evaluate diagnostic accuracy and clinical applicability of a Swedish version of the screening tool 4AT for delirium detection. Method This diagnostic test accuracy study used a quantitative and a qualitative approach and evaluated the patients’ and the health care professionals’ experiences of the tool. Study included 200 patients ≥65 years from a university hospital and a county hospital in two Swedish regions. Medical specialties were geriatric stroke/neurology, geriatric multimorbidity, severe cognitive impairment, orthopaedic, and urology. The translated 4AT was tested against the reference standard DSM-IV-TR criteria, based on the Organic Brain Syndrome scale and patient records. The 4AT was assessed simultaneously and independently by two assessors. Additionally, data was collected through patient record reviews, and questions about applicability to the patients (n = 200) and the assessors (n = 37). Statistical analyses, and qualitative content analyses were conducted. Results By reference standard 18% had delirium, and by 4AT 19%. The overall percent agreement was 88%, AUROC 0.808, sensitivity 0.70 (95% CI 0.51–0.84) and specificity 0.92 (95% CI 0.87–0.96). In the ward for severe cognitive impairment (n = 63) the 4AT was less sensitive and less specific. In the other wards (n = 132) sensitivity was 0.77 (95% CI 0.50–0.93), specificity 0.93 (95% CI 0.87–0.97), and AUROC 0.848. Interrater reliability (Kappa) was 0.918, p = < 0.001 (n = 144). The 4AT was well tolerated by patients, easy to use for health care professionals, and took a few minutes to conduct. Conclusion The Swedish version of 4AT is an accurate and applicable tool to use in clinical practice for detecting delirium in hospitalized patients across different medical specialities, and to use by different professionals and levels of seniority. To improve patient outcomes, we recommend the 4AT to be incorporated in clinical practice in health care settings in Sweden.

Funder

Research Fund at Skaraborg Hospital Sweden.

Stockholm County Council (ALF Project and SU-Region Stockholm Project) Sweden.

Jönköping University

Publisher

Springer Science and Business Media LLC

Subject

Geriatrics and Gerontology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3