A comparison of first-attempt cannulation success of peripheral venous catheter systems with and without wings and injection ports in surgical patients—a randomized trial

Author:

Mörgeli Rudolf,Schmidt Katrin,Neumann Tim,Kruppa Jochen,Föhring Ulrich,Hofmann Pascal,Rosenberger Peter,Falk Elke,Boemke Willehad,Spies Claudia

Abstract

Abstract Background A peripheral venous catheter (PVC) is the most widely used device for obtaining vascular access, allowing the administration of fluids and medication. Up to 25% of adult patients, and 50% of pediatric patients experience a first-attempt cannulation failure. In addition to patient and clinician characteristics, device features might affect the handling and success rates. The objective of the study was to compare the first-attempt cannulation success rate between PVCs with wings and a port access (Vasofix® Safety, B. Braun, abbreviated hereon in as VS) with those without (Introcan® Safety, B. Braun, abbreviated hereon in as IS) in an anesthesiological cohort. Methods An open label, multi-center, randomized trial was performed. First-attempt cannulation success rates were examined, along with relevant patient, clinician, and device characteristics with univariate and multivariate analyses. Information on handling and adherence to use instructions was gathered, and available catheters were assessed for damage. Results Two thousand three hundred four patients were included in the intention to treat analysis. First-attempt success rate was significantly higher with winged and ported catheters (VS) than with the non-winged, non-ported design (IS) (87.5% with VS vs. 78.2% with IS; PChi < .001). Operators rated the handling of VS as superior (rating of “good” or “very good: 86.1% VS vs. 20.8% IS, PChi < .001). Reinsertion of the needle into the catheter after partial withdrawal—prior or during the catheterization attempt—was associated with an increased risk of cannulation failure (7.909, CI 5.989–10.443, P < .001 and 23.023, CI 10.372–51.105, P < .001, respectively) and a twofold risk of catheter damage (OR 1.999, CI 1.347–2.967, P = .001). Conclusions First-attempt cannulation success of peripheral, ported, winged catheters was higher compared to non-ported, non-winged devices. The handling of the winged and ported design was better rated by the clinicians. Needle reinsertions are related to an increase in rates of catheter damage and cannulation failure. Trial registration ClinicalTrials.gov, Identifier: NCT02213965, Date: 12/08/2014.

Funder

BBraun Melsungen AG, Germany

Charité - Universitätsmedizin Berlin

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3