Development of dispersive solid-phase microextraction coupled with high-pressure liquid chromatography for the preconcentration and determination of the selected neonicotinoid insecticides

Author:

Waleng Ngwako Joseas,Selahle Shirley Kholofelo,Mpupa Anele,Nomngongo Philiswa NosizoORCID

Abstract

AbstractNeonicotinoid insecticides have raised a lot of societal concerns due to their environmental ubiquity and unique mode of action. Therefore, it is of great research interest to monitor their occurrence in the environmental waters. However, these compounds exist at low concentrations that is below instrument detection limits. This study reports the applicability of magnetic poly (3 aminobenzoic acid)-based activated carbon (Fe3O4@PABA/AC) composite as an adsorbent in dispersive magnetic solid-phase microextraction (d-MSPME) of neonicotinoid insecticides from wastewater and river water samples. The as-synthesized adsorbent was characterized and confirmed by Fourier transform infrared spectroscopy, scanning electron microscopy, transmission electron microscopy, Brunauer–Emmett–Teller and X-ray diffraction spectroscopy. The analytes of interest were detected and quantified by high-performance liquid chromatography coupled with diode array detector (HPLC–DAD). The parameters affecting the extraction and preconcentration processes, such as pH, extraction time, mass of adsorbent, desorption time and eluent volume, were optimized using fractional factorial design and central composite design. Under optimum conditions, the limits of detection and quantification were in the ranges of 0.41–0.82 µg L−1 and 1.4–2.7 µg L−1, respectively. The linearity ranged from 1.4–700 µg L−1 with correlation of determination (R2) values varied between 0.9933 and 0.9987. The intra-day and inter-day precisions were 0.35–0.75% and 1.7–5.5%, respectively. The spike recovery experiments were conducted to evaluate the accuracy of the d-MSPME analytical method in real samples, and the percentage recoveries ranged from 86.7 to 99.2%. Therefore, this method shows great potential applicability in preconcentrating the pollutants from the environment.

Funder

national research foundation

Publisher

Springer Science and Business Media LLC

Subject

General Physics and Astronomy,General Environmental Science,General Biochemistry, Genetics and Molecular Biology,General Materials Science,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3