Mass fractionation of Rb and Sr isotopes during laser ablation-multicollector-ICPMS: in situ observation and correction

Author:

Yim Sung-Gyun,Jung Min-Ji,Jeong Youn-Joong,Kim Yeongmin,Cheong Albert Chang-sikORCID

Abstract

Abstract Background One of the most critical issues concerning in situ mass spectrometry lies in accounting for elements and molecules that overlap target isotopes of analytical interest in a sample. This study traced the instrumental mass fractionation of Rb and Sr isotopes during laser ablation-multicollector-inductively coupled plasma mass spectrometry (LA-MC-ICPMS) to obtain reliable 87Sr/86Sr ratios for high-Rb/Sr samples. Findings In the LA-MC-ICPMS analysis, Kr interferences were corrected using Ar and He gas blanks measured without ablating material. Contributions from doubly charged Er and Yb ions were corrected using the intensities of half masses and isotopic compositions reported in the literature. After Kr correction, the calculated 166Er2+ intensity of NIST SRM 610 approached the measured intensity at mass 83, and the 173Yb2+/171Yb2+ ratio agreed with the recommended value within error ranges. Kr- and REE2+-stripped peak intensities were further corrected for Rb interference. Use of the Sr mass bias factor for the calculation of measured 87Rb/85Rb yielded 87Sr/86Sr ratios consistent with the recommended and expected values for low-Rb/Sr materials, such as NIST SRM 616, modern shark teeth, and plagioclase collected from Jeju Island, but failed to account for the 87Rb interference from high-Rb/Sr materials including NIST SRM 610 and SRM 612. We calculated in situ mass bias factor of Rb from the known 87Sr/86Sr ratios of the standards and observed a correlation between Rb and Sr mass fractionation, which allowed inference of the Rb bias from the standard run. Reliable 87Sr/86Sr and 85Rb/86Sr ratios were obtained for SRM 610 and SRM 612 using the inferred mass bias factor of Rb calculated by the standard bracketing method. Conclusions This study revealed that Rb and Sr isotopes behave differently during LA-MC-ICPMS and suggests the potential usefulness of the standard bracketing method for measuring the Rb–Sr isotopic compositions of high-Rb/Sr materials.

Funder

Korea Basic Science Institute

Publisher

Springer Science and Business Media LLC

Subject

General Physics and Astronomy,General Environmental Science,General Biochemistry, Genetics and Molecular Biology,General Materials Science,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3