Light-curing process for clear aligners’ attachment reproduction: comparison between two nanocomposites cured by the auxiliary of a new tool

Author:

Gazzani Francesca,Bellisario Denise,Quadrini Fabrizio,Danesi Carlotta,Alberti Andrea,Cozza Paola,Pavoni Chiara

Abstract

Abstract Background Attachments’ configuration play an important role during Clear Aligner Treatment (CAT) for aligner retention and control of movements planned. The aims were to compare the macroscopic morphology of attachments reproduced with flowable (FNC) and conventional (CNC) composites and the effects on them of two light-guide tips with different dimensions. Methods 4 resin casts derived from the initial scan of the same patient were obtained. 10 vestibular attachments were replaced on both upper and lower arches of each model with CNC (Models A, B) and FNC (Models C, D). Each composite was cured by means of the same LED lamp with both regular light-guide (Models A, B) and push and light tool® (Models C, D). The 80 attachments were qualitative analyzed by means of a digital stereo microscope. Surface roughness and waviness measurements were assessed by contact probe surface profiler (TalySurf CLI 2000; Taylor Hobson, Leicester, United Kingdom). Statistical analysis was performed with independent samples t-tests. Significance was established at the P < 0.05 level. Results Model A showed lower values of surface roughness (Ra − 1.41 µm, Rt − 3.46 µm) and waviness (Wa − 2.36 µm, Wt − 10.95 µm) when compared with Model C. Significant reduction of waviness (Wa − 3.85 µm, Wt − 4.90 µm) was observed on Model B when compared with Model D. Significant increase of roughness and waviness parameters (Ra 3.88 µm, Rt 21.07, Wa 2.89 µm, Wt 14.74 µm) was found when CNC sample (Model A) was cured with regular light-guide tip. Higher values (Ra 2.33 µm, Rt 24.07 µm, Wa 1.67 µm, Wt 20.79 µm) were observed after regular light-guide tips curing on FNC sample (Model C). Conclusions CNC resins determine more regular surfaces of attachments profiles. The additional use of a smaller light- guide of the LED push and light tool® allows to improve the macroscopic morphology of the attachments and to maximize light irradiance delivering by enhancing the polymerization process and the integrity of the features during the treatment.

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3