A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol

Author:

Ibrahim Christine Raouf Micheal,Sameh Ahmed,Askar Osama

Abstract

Abstract Background The aim of this study is to investigate, through finite element analysis (FEA), the biomechanical behavior of the built-in angle corrected dental implant versus implant with angled multiunit abutment used in All-On-Four treatment protocol. Methods Two (3D) finite element models of a simplified edentulous mandible were constructed with two different posterior implant designs based on the All-On-Four protocol. Four implants were placed in each model, the two anterior implants were positioned vertically at the lateral incisor/canine sites. Depending on the implant fixture design in posterior area, there are two models created; Model I; the mandible was rehabilitated with four co-axis (4 mm in diameter × 15 mm in length) implants with distally built-in angle corrected implants (24-degree angle correction) .While Model II, the mandible was rehabilitated with four conventional (4 mm in diameter × 14 mm in length) implants with a distally inclined posterior implants (25 degree) and angled multiunit abutments. CAD software (Solidworks© 2017; Dassault Systems Solidworks Corp) was used to model the desired geometry. Axial and inclined Loads were applied on the two models. A Finite element analysis study was done using an efficient software ANSYS© with specified materials. The resultant equivalent Von-Misses stresses (VMS), maximum principal stresses and deformation analysis were calculated for each part (implants and prosthetic components). Results When applying axial and non-axial forces, model II (angled multiunit model) showed higher deformation on the level of Ti mesh about 13.286 μm and higher VMS 246.68 MPa than model I (angle corrected implant). Model I exhibited higher maximum stresses 107.83 MPa than Model II 94.988 MPa but the difference was not statistically significant. Conclusion Within the limitation of the FEA study, although angle correcting implant design is showing higher values in maximum principle stresses compared with angled multiunit abutments, model deformation and resultant VMS increased with angled multiunit abutments. The angle correcting designs at implant level have more promising results in terms of deformation and VMS distribution than angle correction at abutment level.

Funder

Mansoura University

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3