Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity

Author:

Zhou Huangjun,Ye Sixian,Liu Min,Feng Hao,Wen CaiORCID

Abstract

Abstract Background This in vitro study aimed to provide evidence regarding the selection of hole diameters of implant crowns to reduce excess cement extrusion at the abutment margin, and to examine the maintenance of their retention capacity in anterior and posterior cement-retained implant crowns. Methods Six groups of implant crowns were prepared according to the position of the teeth and the size of their holes as follows: anterior crown without hole (ANH), anterior crown with 1-mm mini venting hole (AMH), anterior crown with 2.5-mm regular screw access hole (ARH), posterior crown without hole (PNH), posterior crown with 1-mm mini venting hole (PMH), and posterior crown with 2.5-mm regular screw access hole (PRH). Temporary cement was used to bond the crowns to the abutments. The mean amount of excess cement extrusion among the different groups at the abutment margin was calculated. Retentive strength under different hole designs was measured as the dislocation force of the crown using a universal testing machine. One-way ANOVA and Welch’s t-test were used to analyze the results. Results The average amounts of extruded excess cement were 18.96 ± 0.64, 1.78 ± 0.41, and 1.30 ± 0.41 mg in the ANH, AMH, and ARH groups, respectively, and 14.87 ± 0.36, 1.51 ± 0.40, and 0.82 ± 0.22 mg in the PNH, PMH, and PRH groups, respectively. The hole opening in the crowns could significantly reduce residual cement regardless of its size (p < 0.001). The mean retentive strengths were 54.16 ± 6.00, 47.63 ± 13.54, and 31.99 ± 7.75 N in the ANH, AMH, and ARH groups, respectively, and 57.84 ± 10.19, 53.22 ± 6.98, and 39.48 ± 5.12 N in the PNH, PMH, and PRH groups, respectively. The retention capacity of the implant crown deteriorated rapidly as the holes on the crown surface enlarged. Conclusions The presence of a hole on the implant crown reduced the amount of excess cement. The retention ability of the implant crowns deteriorated as the size of the hole increased. Considering the esthetic effect of the crown and the possible influence on crown retention, an implant crown with a 1-mm mini venting hole is a better clinical choice than the one with a 2.5-mm regular screw access hole.

Funder

Strategic cooperation project between Sichuan University and Luzhou Municipal Government

Medical Association of Sichuan Province

Sichuan Provincial Department of Education

Southwest Medical University

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3