Abstract
Although placing a vent hole on the occlusal surface of the implant crown can reduce cervical marginal cement extrusion, it has disadvantages. Transferring the hole to the buccal or lingual surface of the posterior implant crown could therefore be an alternative solution. This study investigated the effect of transferring the vent hole to the lateral side of the implant posterior crown on the hydrodynamics of excess cement extrusion and the crown’s retention ability. Specially fabricated posterior implant crowns were divided into five groups: crowns with an occlusal hole (OH), occlusal lateral hole (OLH), middle lateral hole (MLH), cervical lateral hole (CLH), and no hole (NH). Each set of implant analog-abutment-crown specimens was wrapped in a polymethylacrylate base. The base of the implant crown was divided into four 90-degree quadrants along the diagonal of the square base with a pen mark. Cement was used to bond the crowns and the abutments, and the weight of cement extrusions at the vent holes and the abutment cervical margins were calculated. The distribution of cement extrusion at the margin was photographed in each quadrant, and the areas of surface coverage of cement extrusion were compared with ImageJ software. Retentive strength was measured as the dislocation force using a universal testing machine. One-way analysis of variance was used for result analysis. The cervical marginal cement extrusions of crowns with lateral holes (OLH, MLH, and CLH) were significantly less than that of NH crowns (P<0.05), but more than that of OH crowns (P<0.05). Subgroup analysis among the lateral hole groups indicated that the higher the position of the lateral hole, the lower the weight of the cement extrusion, and the smaller the total distribution area of cement extrusion. The cement extrusion distribution area was larger in the quadrant with the hole than in those opposite and next to the hole. Retention strength comparison indicated no significant difference between crowns with NH, OH, or lateral holes. Transferring the vent hole of the posterior implant crown to the lateral side could reduce cement extrusion at the cervical margin while reducing retention strength deterioration and the esthetic drawbacks caused by occlusal hole opening.
Funder
Southwest Medical University
Innovation and Entrepreneurship Training Program of Southwest Medical University
Graduate School of Southwest Medical University
Strategic cooperation project between Sichuan University and Luzhou Municipal Government
Publisher
Public Library of Science (PLoS)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献