Biomechanical analysis of stress around the tilted implants with different cantilever lengths in all-on-4 concept

Author:

Wang Qi,Zhang Zhen-zhen,Bai Shi-zhu,Zhang Shao-feng

Abstract

AbstractBackgroundMany clinical studies have reported the high success rate of the All-on-4 concept. In the present study, we aimed to compare the stress distribution with different tilted distal implants and cantilever lengths in an All-on-4 system using the two-dimensional photoelastic method and to establish the All-on-4 implant photoelastic model by computer-aided design (CAD) and rapid prototyping (RP). MethodsThe data of the human edentulous mandible were acquired by computed tomography (CT). Three human edentulous mandible All-on-4 implant models with different distally inclined implant holes were fabricated using Mimic, Geomagic Studio software, and a light solidifying fast shaping machine. Then the final photoelastic models were established through the traditional method. Each of the three models had four NobelSpeedy Replace implants between the interforaminal regions. The two posterior implants were placed 0, 15, and 45 degrees distally before the mental foramen. The four implants were splinted by wrought cobalt-chromium alloy frameworks. Each of the three photoelastic models was submitted to a 150 N vertical load at five points on the framework: the central fossa of the mandibular first molar, and 0 mm, 5 mm, 10 mm, and 15 mm of the cantilever length. The stress produced in the models was photographed with a digital camera, and the highest value of the stressed fringe pattern was recorded.ResultsThe All-on-4 implant photoelastic model established by CAD and RP was highly controllable and easy to modify. The position and inclination of implants were accurate, and the frameworks could be passively emplaced. The stress values were higher around a single tilted implant compared with the distal implant in All-on-4 with the same inclination. The 0-degree distal implant and 45-degree distal implant demonstrated the highest and lowest stress when loading at the central fossa of the mandibular first molar, respectively. With the same inclination of distal implant, the peri-implant bone stress increased as the length of cantilever increased.ConclusionThe method of establishing the All-on-4 implant photoelastic model by CAD and RP was highly controllable, convenient, fast, and accurate. The tilted implants splinted in the fully fixed prosthesis with reduced cantilever lengths did not increase the stress level compared with the vertical distal implants.And this illustrated that the influence of cantilever on stress distribution was greater than the influence of implant inlination.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

General Dentistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3