Biomechanical Analysis of Titanium Dental Implants in the All-on-4 Treatment with Different Implant–Abutment Connections: A Three-Dimensional Finite Element Study

Author:

Wang Pei-Shuang1,Tsai Ming-Hsu2ORCID,Wu Yu-Ling1,Chen Hung-Shyong23,Lei Yao-Ning1,Wu Aaron Yu-Jen1ORCID

Affiliation:

1. Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan

2. Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan

3. Center for Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833, Taiwan

Abstract

The type of implant-abutment connection is one of the factors influencing the distribution of occlusal forces. This study aims to investigate the biomechanical performance of the mandibular all-on-4 treatment with different implant–abutment connections. Two connection types with 30° abutments and 18-mm implant fixtures were chosen for the posterior implants of the all-on-4 assembly. For the external hexagon connection (EHC) group, the implants with 4 mm in diameter were used. For the internal hexagon connection (IHC) group, we selected implants with 4.3 mm in diameter. A vertical force of 190 N was applied to the cantilever region. The FEA results indicated that the most stressed region in the two groups was prosthetic screws, followed by multi-unit abutments (MUAs). The lowest values of von Mises stress were both observed on the bone. The peak stress value of the implant screw and implant fixture in the EHC group were 37.75% and 33.03% lower than the IHC group, respectively. For stress distribution patterns, the load force tended to be concentrated at locations where components were interconnected. The EHC and IHC are clinically durable under the tested loading conditions, but the prosthetic screws and MUAs can be the weak point on the posterior implant within the mandibular all-on-four assembly. The peak stress values of implant screw and implant fixture in the EHC groups were lower than the IHC group.

Funder

Chang Gung Medical Foundation and Cheng Shiu University

Publisher

MDPI AG

Subject

Biomedical Engineering,Biomaterials

Reference51 articles.

1. (2018, January 17). Ministry of Health and Welfare of Taiwan, Available online: https://dep.mohw.gov.tw/DOOH/lp-6553-124.html.

2. (2023, September 25). Centers for Disease Control and Prevention, Available online: https://stacks.cdc.gov/view/cdc/82756/cdc_82756_DS1.pdf.

3. Soboleva, U., and Rogovska, I. (2022). Edentulous Patient Satisfaction with Conventional Complete Dentures. Medicina, 58.

4. Optimum selection of the dental implant diameter and length in the posterior mandible with poor bone quality—A 3D finite element analysis;Li;Appl. Math. Model.,2011

5. “All-on-Four” immediate-function concept with Brånemark system implants for completely edentulous mandibles retrospective clinical study;Malo;Clin. Implant Dent. Relat. Res.,2003

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3