Background
The aim of this study was to assess the accuracy of virtual planning of computer-guided surgery based on the actual outcomes of clinical dental implant placement.
Methods
This retrospective study enrolled patients among whom implant treatment was planned using computer-guided surgery with cone beam computed tomography (CBCT). The patients who received implant according to the guide with the flapless and flapped approach were classified as group 1 and 2, respectively, and the others who could not be placed according to the guide were allocated to the drop-out group. The accuracy of implant placement was evaluated with the superimposition of CBCT.
Results
We analyzed differences in the deviated distance of the entrance point and deviated angulation of the insertion of implant fixtures. With regard to the surgical approach, group 2 exhibited greater accuracy compared to group 1 in deviation distance (2.22 ± 0.88 and 3.18 ± 0.89 mm, respectively, P < 0.001) and angulation (4.27 ± 2.30 and 6.82 ± 2.71°, respectively, P = 0.001). The limitations of guided surgery were discussed while considering the findings from the drop-out group.
Conclusions
Computer-guided surgery demonstrates greater accuracy in implant placement with the flapless approach. Further research should be conducted to enhance the availability of guides for cases with unfavorable residual bone conditions.
Publisher
Springer Science and Business Media LLC
Reference38 articles.
1. Al Yafi F, Camenisch B, Al-Sabbagh M. Is digital guided implant surgery accurate and reliable? Dent Clin N Am. 2019;63(3):381–97.
2. D’Haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontology 2000. 2017;73(1):121–33.
3. Llamas-Monteagudo O, Girbés-Ballester P, Viña-Almunia J, Peñarrocha-Oltra D, Peñarrocha-Diago M. Clinical parameters of implants placed in healed sites using flapped and flapless techniques: a systematic review. Med Oral Patol Oral Cir Bucal. 2017;22(5):e572–81.
4. Maier FM. Initial crestal bone loss after implant placement with flapped or flapless surgery-a prospective cohort study. Int J Oral Maxillofac Implants. 2016;31(4):876–83.
5. Yadav R, Agrawal KK, Rao J, Anwar M, Alvi HA, Singh K, Himanshu D. Crestal bone loss under delayed loading of full thickness versus flapless surgically placed dental implants in controlled type 2 diabetic patients: a parallel group randomized clinical trial. J Prosthodont. 2018;27(7):611–7.
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献