Accuracy of different types of surgical guides for dental implant placement

Author:

Drobyshev Alexey Yu.ORCID,Vaulina Daria S.ORCID,Redko Nukolay A.ORCID,Pankov Egor V.ORCID

Abstract

BACKGROUND: The advancement of three-dimensional (3D) imaging techniques and implant planning software has contributed to a wide adoption of prosthetically guided implant placement. AIM: This study aims to examine the virtual planning accuracy of dental implant placement using various surgical templates. MATERIALS AND METHODS: The study included 24 partially and fully edentulous patients. Patients were divided into four groups using a parallel group design: templates for pilot osteotomy made by 3D printing (group I), full-guided templates made by 3D printing (group II), surgical templates for pilot osteotomy made by milling (group III), and full-guided templates made by milling (group IV). The accuracy of dental implant position was assessed by comparing the planned and actual position of the implants using preoperative and postoperative computed tomography. Three mean deviation parameters (angular, at the neck position, and at the apex position) were defined to evaluate the discrepancy between the planned and placed implant positions. RESULTS: The best results were obtained in group III, where dental implant placement was performed using milled surgical templates for pilot osteotomy. The mean angular deviation, deviation at the neck, and deviation at the apex of the implant were 4.013.21, 0.380.23 mm, and 0.560.51 mm, respectively (p 0.001 for all). The mean angular deviation in the group that used milled surgical templates for the full-guided osteotomy was 5.665.38, with deviations at the implant neck and apex of 0.730.71 and 0.680.67 mm, respectively (p 0.001 for all), demonstrating high accuracy of implant placement within the safety zone. Lower accuracy scores were found in groups I and II, when 3D printed templates were used. The mean angular deviation in the pilot osteotomy group was 7.715.94, the mean deviation at the neck was 1.021.07 mm, and the mean deviation at the apex of the implant was 1.401.69 mm (p 0.001 for all). In the group for full-guided osteotomy, the mean angular deviation, deviation at the neck, and deviation at the apex of the implant were 6.46.21, 0.580.45 mm, and 0.830.80 mm, respectively (p 0.001 for all). CONCLUSION: The use of surgical templates in dental implant placement allows for a high accuracy in implant position. Milled surgical templates for dental implants are more accurate than 3D-printed templates, allowing us to introduce surgical templates into clinical practice to improve dental care quality.

Publisher

ECO-Vector LLC

Subject

Linguistics and Language,Anthropology,History,Language and Linguistics,Cultural Studies

Reference31 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3