Author:
Meng Xuehuan,Wang Chunjuan,Xu Wenjie,Wang Rui,Zheng Leilei,Wang Chao,Aversa Raffaella,Fan Yubo
Abstract
Abstract
Background
Controlling the 3D movement of central incisors during tooth extraction cases with clear aligners is important but challenging in invisible orthodontic treatment. This study aimed to explore the biomechanical effects of central incisors in tooth extraction cases with clear aligners under different power ridge design schemes and propose appropriate advice for orthodontic clinic.
Methods
A series of Finite Element models was constructed to simulate anterior teeth retraction or no retraction with different power ridge designs. These models all consisted of maxillary dentition with extracted first premolars, alveolar bone, periodontal ligaments and clear aligner. And the biomechanical effects were analysed and compared in each model.
Results
For the model of anterior teeth retraction without power ridge and for the model of anterior teeth no retraction with a single power ridge, the central incisors exhibited crown lingual inclination and relative extrusion. For the model of anterior teeth no retraction with double power ridges, the central incisors tended to have crown labial inclination and relative intrusion. For the model of anterior tooth retraction with double power ridges, the central incisors exhibited a similar trend to the first kind of model, but as the depth of the power ridge increased, there was a gradual decrease in crown retraction value and an increase in crown extrusion value. The simulated results showed that von-Mises stress concentration was observed in the cervical and apical regions of the periodontal ligaments of the central incisors. The clear aligner connection areas of adjacent teeth and power ridge areas also exhibited von-Mises stress concentration and the addition of power ridge caused the clear aligner to spread out on the labial and lingual sides.
Conclusions
The central incisors are prone to losing torque and extruding in tooth extraction cases. Double power ridges have a certain root torque effect when there are no auxiliary designs, but they still cannot rescue tooth inclination during tooth retraction period. For tooth translation, it may be a better clinical procedure to change the one-step aligner design to two-step process: tilting retraction and root control.
Funder
Chongqing Talent Program: Innovative leading talents
Chongqing Medical Scientific Research Project
Program for Youth Innovation in Future Medicine, Chongqing Medical University
National Natural Science Foundation of China
Natural Science Foundation of Beijing
the Fundamental Research Funds for the Central Universities, the 111 Project
Publisher
Springer Science and Business Media LLC
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献