Abstract

AbstractMany studies have shown that using a computer-aided detection (CAD) system does not significantly improve diagnostic accuracy in radiology, possibly because radiologists fail to interpret the CAD results properly. We tested this possibility using screening mammography as an illustrative example. We carried out two experiments, one using 28 practicing radiologists, and a second one using 25 non-professional subjects. During each trial, subjects were shown the following four pieces of information necessary for evaluating the actual probability of cancer in a given unseen mammogram: the binary decision of the CAD system as to whether the mammogram was positive for cancer, the true-positive and false-positive rates of the system, and the prevalence of breast cancer in the relevant patient population. Based only on this information, the subjects had to estimate the probability that the unseen mammogram in question was positive for cancer. Additionally, the non-professional subjects also had to decide, based on the same information, whether to recall the patients for additional testing. Both groups of subjects similarly (and significantly) overestimated the cancer probability regardless of the categorical CAD decision, suggesting that this effect is not peculiar to either group. The misestimations were not fully attributable to causes well-known in other contexts, such as base rate neglect or inverse fallacy. Non-professional subjects tended to recall the patients at high rates, even when the actual probably of cancer was at or near zero. Moreover, the recall rates closely reflected the subjects’ estimations of cancer probability. Together, our results show that subjects interpret CAD system output poorly when only the probabilistic information about the underlying decision parameters is available to them. Our results also highlight the need for making the output of CAD systems more readily interpretable, and for providing training and assistance to radiologists in evaluating the output.

Funder

u.s. army

Publisher

Springer Science and Business Media LLC

Subject

Cognitive Neuroscience,Experimental and Cognitive Psychology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3