Evaluation of automated microvascular flow analysis software AVA 4: a validation study

Author:

Guay Christian S.,Khebir Mariam,Shiva Shahiri T.,Szilagyi Ariana,Cole Erin Elizabeth,Simoneau Gabrielle,Badawy Mohamed

Abstract

Abstract Background Real-time automated analysis of videos of the microvasculature is an essential step in the development of research protocols and clinical algorithms that incorporate point-of-care microvascular analysis. In response to the call for validation studies of available automated analysis software by the European Society of Intensive Care Medicine, and building on a previous validation study in sheep, we report the first human validation study of AVA 4. Methods Two retrospective perioperative datasets of human microcirculation videos (P1 and P2) and one prospective healthy volunteer dataset (V1) were used in this validation study. Video quality was assessed using the modified Microcirculation Image Quality Selection (MIQS) score. Videos were initially analyzed with (1) AVA software 3.2 by two experienced investigators using the gold standard semi-automated method, followed by an analysis with (2) AVA automated software 4.1. Microvascular variables measured were perfused vessel density (PVD), total vessel density (TVD), and proportion of perfused vessels (PPV). Bland–Altman analysis and intraclass correlation coefficients (ICC) were used to measure agreement between the two methods. Each method’s ability to discriminate between microcirculatory states before and after induction of general anesthesia was assessed using paired t-tests. Results Fifty-two videos from P1, 128 videos from P2 and 26 videos from V1 met inclusion criteria for analysis. Correlational analysis and Bland–Altman analysis revealed poor agreement and no correlation between AVA 4.1 and AVA 3.2. Following the induction of general anesthesia, TVD and PVD measured using AVA 3.2 increased significantly for P1 (p < 0.05) and P2 (p < 0.05). However, these changes could not be replicated with the data generated by AVA 4.1. Conclusions AVA 4.1 is not a suitable tool for research or clinical purposes at this time. Future validation studies of automated microvascular flow analysis software should aim to measure the new software’s agreement with the gold standard, its ability to discriminate between clinical states and the quality thresholds at which its performance becomes unacceptable.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3