Interobserver reliability for manual analysis of sidestream darkfield videomicroscopy clips after resizing in ImageJ

Author:

Lala Raushan C. B.ORCID,Homes Ryan A. P.,Lipman Jeffrey,Midwinter Mark J.

Abstract

Abstract Background Direct assessment of microcirculatory function remains a critical care research tool but approaches for analysis of microcirculatory videomicroscopy clips are shifting from manual to automated algorithms, with a view to clinical application in the intensive care unit. Automated analysis software associated with current sidestream darkfield videomicroscopy systems is demonstrably unreliable; therefore, semi-automated analysis of captured clips should be undertaken in older generations of software. We present a method for capture of microcirculatory clips using current version videomicroscope hardware and resizing of clips to allow compatibility with legacy analysis software. The interobserver reliability of this novel approach is examined, in addition to a comparison of this approach with the current generation of automated analysis software. Results Resizing microcirculatory clips did not significantly change image quality. Assessment of bias between observers for manual analysis of resized clips; and between manually analysed clips and automated software analysis was undertaken by Bland–Altman analysis. Bias was demonstrated for all parameters for manual analysis of resized clips (total vessel density = 6.8, perfused vessel density = 6.3, proportion of perfused vessels = − 8.79, microvascular flow index = − 0.08). Marked bias between manual analysis and automated analysis was also evident (total vessel density = 16.6, perfused vessel density = 16.0, proportion of perfused vessels = 1.8). The difference between manual and automated analysis was linearly related to the magnitude of the measured parameter. Conclusions Poor reliability of automated analysis is a significant hurdle for clinical translation of microcirculatory monitoring. The method presented here allows capture of microcirculatory clips using current hardware that are backwards compatible with older versions of manual analysis software. We conclude that this approach is appropriate for research applications in the intensive care unit, however the time delay to results limits utility for clinical translation.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3