Abstract
Abstract
Background
Subcutaneous immunotherapy (SCIT) is an effective treatment for allergic rhinoconjunctivitis. However, adverse events, including life-threatening systemic reactions, may occur. The purpose of this project is to identify risk factors for systemic reactions to SCIT and to provide practice-based solutions using a quality improvement (QI) framework.
Methods
A QI initiative was performed in a hospital-based, Canadian Allergy clinic administering SCIT in a 12-month period.
Results
A total of 4242 injections of SCIT were performed over a period of 12 months. Of these, 10 injections resulted in a systemic reaction requiring epinephrine administration (i.e., an incidence of 1 in 424 injections, or 0.24%). Eight patients had at least one documented risk factor for a systemic reaction, and six had multiple risk factors. Major risk factors included seasonal exacerbation of allergic rhinitis, uncontrolled asthma, and an error in route of administration. All reactions occurred with the highest allergen extract concentration.
Conclusion
This QI initiative highlights the need for improved patient and health care practitioner education and pre-administration screening. We suggest several considerations for SCIT administration: provide patients with written information on safety; screen patients before injections, including a review of treatment plan adherence and asthma control; adjust dosing to slow down buildup of the most concentrated immunotherapy extract, particularly in high risk patients; and apply additional safety measures in patients with multiple risk factors.
Publisher
Springer Science and Business Media LLC
Subject
Pulmonary and Respiratory Medicine,Immunology,Immunology and Allergy
Reference28 articles.
1. Kim H, Moote W, Waserman S. Immunotherapy manual. Canadian Society of Allergy and Clinical Immunology; 2016. https://csaci.ca/wp-content/uploads/2017/12/IT-Manual-2016-5-July-2017-rev.pdf. Accessed 31 May 2021.
2. Cox L, Nelson H, Lockey R, Calabria C, Chacko T, Finegold I, et al. Allergen immunotherapy: a practice parameter third update. J Allergy Clin Immunol. 2011;127(1):S1-55.
3. James C, Bernstein DI. Allergen immunotherapy: an updated review of safety. Curr Opin Allergy Clin Immunol. 2017;17(1):55.
4. Epstein TG, Liss GM, Berendts KM, Bernstein DI. AAAAI/ACAAI Subcutaneous Immunotherapy Surveillance Study (2013–2017): fatalities, infections, delayed reactions, and use of epinephrine autoinjectors. J Allergy Clin Immunol In Pract. 2019;7(6):1996–2003.
5. Windom HH, Lockey RF. An update on the safety of specific immunotherapy. Curr Opin Allergy Clin Immunol. 2008;8(6):571–6.
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献