Internal jugular vein distensibility variation and inferior vena cava collapsibility variation with fluid resuscitation as an indicator for fluid management in spontaneously breathing septic patients

Author:

Elsaeed Ahmad Mohamad RashadORCID,Nor El-Din Bassel Mohamed Essam,El Taher Waleed Abdelmegeed Mohamed,Mostafa Raham HasanORCID,Saleh Ashraf NabilORCID

Abstract

Abstract Background Sepsis is one of the leading causes of death in ICU patients. Fluid resuscitation is the main target in septic patients. Proper fluid administration is needed in septic patients to overcome generalized vasodilatation and capillary leak, this capillary leak itself may cause tissue edema and worsen septic patients. On the other hand, vasopressors may improve tissue perfusion or worsen tissue hypoxia. Therefore, predictors for fluid responsiveness are urgently needed. However, many studies have found static indicators useless. That is why dynamic predictors for fluid responsiveness are attracting growing interest to optimize patients. Our goal is to assess the predictive power of internal jugular vein distensibility index and inferior vena cava collapsibility index for fluid responsiveness in spontaneously breathing septic patients. Forty adult septic patients were enrolled from a single university teaching hospital’s ICU. We measured the Internal jugular distensibility index (IJV-DI) and Inferior vena cava collapsibility index (IVC-CI) in spontaneously breathing septic patients. Patients were considered responders if they had a change in cardiac index (≥ 15%) after fluid resuscitation with 7 ml/kg crystalloid. The main outcome measure is predictive power of Internal jugular vein distensibility index and Inferior vena cava collapsibility index. Results Data from 40 spontaneously breathing septic patients were analyzed. Sixty percent of the patients were fluid responder. The areas under curve of receiver operating characteristic for Internal jugular vein distensibility index and Inferior vena cava collapsibility index to predict fluid responsiveness were 0.96 and 0.97, respectively. IJV-DI (> 17.56%) was predictive of fluid responsiveness with 95.83% sensitivity and 87.5% specificity. IVC-CI (> 35%) was predictive of fluid responsiveness with 95.8% sensitivity and 93.7% specificity. Conclusions Both IJV-DI and IVC-CI have near good predictive value for fluid responsiveness in spontaneously breathing septic patients.

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3