Measurement site of inferior vena cava diameter affects the accuracy with which fluid responsiveness can be predicted in spontaneously breathing patients: a post hoc analysis of two prospective cohorts

Author:

Caplan Morgan,Durand Arthur,Bortolotti Perrine,Colling Delphine,Goutay Julien,Duburcq Thibault,Drumez Elodie,Rouze Anahita,Nseir Saad,Howsam Michael,Onimus Thierry,Favory Raphael,Preau SebastienORCID

Abstract

Abstract Background The collapsibility index of the inferior vena cava (cIVC) has potential for predicting fluid responsiveness in spontaneously breathing patients, but a standardized approach for measuring the inferior vena cava diameter has yet to be established. The aim was to test the accuracy of different measurement sites of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with sepsis-related circulatory failure and examine the influence of a standardized breathing manoeuvre. Results Among the 81 patients included in the study, the median Simplified Acute Physiologic Score II was 34 (24; 42). Sepsis was of pulmonary origin in 49 patients (60%). Median volume expansion during the 24 h prior to study inclusion was 1000 mL (0; 2000). Patients were not severely ill: none were intubated, only 20% were on vasopressors, and all were apparently able to perform a standardized breathing exercise. Forty-one (51%) patients were responders to volume expansion (i.e. a ≥ 10% stroke volume index increase). The cIVC was calculated during non-standardized (cIVC-ns) and standardized breathing (cIVC-st) conditions. The accuracy with which both cIVC-ns and cIVC-st predicted fluid responsiveness differed significantly by measurement site (interaction p < 0.001 and < 0.0001, respectively). Measuring inferior vena cava diameters 4 cm caudal to the right atrium predicted fluid responsiveness with the best accuracy. At this site, a standardized breathing manoeuvre also significantly improved predictive power: areas under ROC curves [mean and (95% CI)] for cIVC-ns = 0.85 [0.78–0.94] versus cIVC-st = 0.98 [0.97–1.0], p < 0.001. When cIVC-ns is superior or equal to 33%, fluid responsiveness is predicted with a sensitivity of 66% and a specificity of 92%. When cIVC-st is superior or equal to 44%, fluid responsiveness is predicted with a sensitivity of 93% and a specificity of 98%. Conclusion The accuracy with which cIVC measurements predict fluid responsiveness in spontaneously breathing patients depends on both the measurement site of inferior vena cava diameters and the breathing regime. Measuring inferior vena cava diameters during a standardized inhalation manoeuvre at 4 cm caudal to the right atrium seems to be the method by which to obtain cIVC measurements best-able to predict patients’ response to volume expansion.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3