Background
The positron emitting isotope fluorine-18 (18F) possesses almost ideal physicochemical properties for the development of radiotracers for diagnostic molecular imaging employing positron emission tomography (PET). 18F in its nucleophilic anionic 18F− form is usually prepared by bombarding an enriched 18O water target with protons of various energies between 5 and 20 MeV depending on the technical specifications of the cyclotron. Large thick-target yields between 5 and 14 GBq/µA can be obtained, enough to prepare large batches of radiotracers capable to serve a considerable contingent of patients (50 + per clinical batch). The overall yield of the radiotracer however depends on the efficiency of the 18F labeling chemistry. The Silicon Fluoride Acceptor chemistry (SiFA) has introduced a convenient and highly efficient way to provide clinical peptide-based 18F-radiotracers in a kit-like procedure matching the convenience of 99mTc radiopharmaceuticals.
Main body
A radiotracer’s clinical success primarily hinges on whether its synthesis can be automated. Due to its simplicity, the SiFA chemistry, which is based on isotopic exchange (18F for 19F), does not only work in a manual setup but has been proven to be automatable, yielding large batches of 18F-radiotracers of high molar activity (Am). The production of SiFA radiotracer can be centralized and the radiopharmaceutical be distributed via the “satellite” principle, where one production facility economically serves multiple clinical application sites. Clinically validated tracers such as [18F]SiTATE and [18F]Ga-rhPSMA-7/-7.3 have been synthesized in an automated synthesis unit under good manufacturing practice conditions and used in large patient cohorts. Communication of common guidelines and practices is warranted to further the dissemination of SiFA radiopharmaceuticals and to give easy access to this technology.
Conclusion
This current review highlights the most recent achievements in SiFA radiopharmaceutical automation geared towards large batch production for clinical application. Best practice advice and guidance towards a facilitated implementation of the SiFA technology into new and already operating PET tracer production facilities is provided. A brief outlook spotlights the future potential of SiFA radiochemistry within the landscape of non-canonical labeling chemistries.
Publisher
Springer Science and Business Media LLC
Subject
Pharmacology (medical),Pharmacology,Radiology, Nuclear Medicine and imaging,Analytical Chemistry
Reference22 articles.
1. Archibald SJ, Allott L. The aluminium-[18F]fluoride revolution: simple radiochemistry with a big impact for radiolabelled biomolecules. EJNMMI Radiopharm Chem. 2021;6:30. 2. Bernard-Gauthier V, Bailey JJ, Liu Z, Wängler B, Wängler C, Jurkschat K, Perrin DM, Schirrmacher R. From unorthodox to established: the current status of 18F-trifluoroborate- and 18F-SiFA-based radiopharmaceuticals in PET nuclear imaging. Bioconjugate Chem. 2016;27:267–79. 3. Beyer L, Gosewisch A, Lindner S, Völter F, Mittlmeier LM, Tiling R, Brendel M, Cyran CC, Unterrainer M, Rübenthaler J, Auernhammer CJ, Spitzweg C, Böning G, Gildehaus FJ, Jurkschat K, Wängler C, Wängler B, Schirrmacher R, Wenter V, Todica A, Bartenstein P, Ilhan H. Dosimetry and optimal scan time of [18F]SiTATE-PET/CT in patients with neuroendocrine tumours. Eur J Nucl Med Mol Imaging. 2021;48:3571–81. 4. Eschbach RS, Hofmann M, Späth L, Sheikh GT, Delker A, Lindner S, Jurkschat K, Wängler C, Wängler B, Schirrmacher R, Tiling R, Brendel M, Wenter V, Dekorsy FJ, Zacherl MJ, Todica A, Ilhan H, Grawe F, Cyran CC, Unterrainer M, Rübenthaler J, Knösel T, Paul T, Boeck S, Westphalen CB, Spitzweg C, Auernhammer CJ, Bartenstein P, Unterrainer LM, Beyer L. Comparison of somatostatin receptor expression in patients with neuroendocrine tumours with and without somatostatin analogue treatment imaged with [18F]SiTATE. Front Oncol. 2023;13:992316. 5. Gower-Fry L, Kronemann T, Dorian A, Pu Y, Jaworski C, Wängler C, Bartenstein P, Beyer L, Lindner S, Jurkschat K, Wängler B, Bailey JJ, Schirrmacher R. Recent advances in the clinical translation of silicon fluoride acceptor (SiFA) 18F-radiopharmaceuticals. Pharmaceuticals. 2021;14:701.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|