Left ventricular unloading therapy using Impella 5.5 after emergency surgery for acute myocardial infarction mechanical complication: a case report

Author:

Iino Kenji,Yamamoto Yoshitaka,Ueda Hideyasu,Takemura Hirofumi

Abstract

Abstract Background Following an acute myocardial infarction (AMI), surgery for left ventricular free wall rupture (LVFWR) and ventricular septal rupture (VSR) has a high in-hospital mortality rate, which has not improved significantly over time. Unloading the LV is critical to preventing excessive stress on the repair site and avoiding problems such as bleeding, leaks, patch dehiscence, and recurrence of LVFWR and VSR because the tissue is so fragile. We present two cases of patients who used Impella 5.5 for LV unloading following emergency surgery for AMI mechanical complications. Case presentation A 76-year-old male STEMI patient underwent fibrinolysis of the distal right coronary artery. Three days later, he passed out and went into shock. Echocardiography revealed a cardiac tamponade. We found an oozing-type LVFWR on the posterolateral wall and treated it with a non-suture technique using TachoSil. Before the patient was taken off CPB, Impella 5.5 was inserted into the LV via a 10 mm synthetic graft connected to the right axillary artery. We kept the flow rate above 4.0 to 4.5 L/min until POD 3 to reduce LV wall tension while minimizing pulsatility. On POD 6, we weaned the patient from Impella 5.5. A postoperative cardiac CT scan showed no contrast leakage from the LV. However, a cerebral hemorrhage on POD 4 during heparin administration complicated his hospitalization. Case 2: A diagnosis of cardiogenic shock caused by STEMI occurred in an 84-year-old male patient, who underwent PCI of the LAD with IABP support. Three days after PCI, echocardiography revealed VSR, and the patient underwent emergency VSR repair with two separate patches and BioGlue applied to the suture line between them. Before weaning from CPB, we implanted Impella 5.5 in the LV and added venoarterial extracorporeal membrane oxygenation (VA-ECMO) support for right heart failure. The postoperative echocardiography revealed no residual shunt. Conclusions Patients undergoing emergency surgery for mechanical complications of AMI may find Impella 5.5 to be an effective tool for LV unloading. The use of VA-ECMO in conjunction with Impella may be an effective strategy for managing VSR associated with concurrent right-sided heart failure.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3