Abstract Background Insufflation of carbon dioxide (CO2) into the operative field to prevent cerebral or myocardial damage by air embolism is a well known strategy in open-heart surgery. However, here is no general consensus on the best delivery approach. Methods From January 2018 to November 2021, we retrospectively collected data of one hundred consecutive patients undergoing minimally invasive mitral valve repair (MIMVR). Of these, fifty patients were insufflated with continuous CO2 1 min before opening the left atrium and ended after its closure, and fifty patients were insufflated with one shot CO2 10 min before the start of left atrium closure. The primary outcome of the study was the incidence of transient post-operative cognitive disorder, in particular agitation and delirium at discontinuation of anesthesia, mechanical ventilation (MV) duration and intensive care unit (ICU) length of stay. Results In all patients that received continuous field flooding CO2, correction of ventilation for hypercapnia during cardiopulmonary bypass (CPB) was applied with an increase of mean sweep gas air (2.5 L) and monitoring of VCO2 changes. One patient vs. 9 patients of control group reported agitation at discontinuation of anesthesia (p = 0.022). MV duration was 14 ± 3 h vs. 27 ± 4 h (p = 0.016) and ICU length of stay was 33 ± 4 h vs. 42 ± 5 h (p = 0.029). A significant difference was found in the median number of total micro-emboli recorded from release of cross-clamp until 20 min after end of CPB (154 in the continuous CO2 group vs. 261 in the one-shot CO2 control group; p < 0.001). Total micro-emboli from the first 15 min after the release of cross-clamp was 113 in the continuous CO2 group vs. 310 in the control group (p < 0.001). In the continuous CO2 group, the median number of detectable micro-emboli after CPB fell to zero 9 ± 5 min after CPB vs. 19 ± 3 min in the control group (p = 0.85). Conclusion Continuous field flooding insufflation of CO2 in MIMVR is associated with a lower incidence of micro-emboli and of agitation at discontinuation of anesthesia, along with improved MV duration and ICU length of stay.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Develop of endocavitary suction device for MiECC on minimally invasive mitral valve surgery;Journal of Cardiothoracic Surgery;2024-03-27

2. Valve surgery — A review of the 2022 literature;Zeitschrift für Herz-,Thorax- und Gefäßchirurgie;2023-06-08

3. Cardiac Surgery 2022 Reviewed;The Thoracic and Cardiovascular Surgeon;2023-05-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3