Effect of CO 2 Insufflation on the Number and Behavior of Air Microemboli in Open-Heart Surgery

Author:

Svenarud P.1,Persson M.1,van der Linden J.1

Affiliation:

1. From the Department of Cardiothoracic Surgery and Anesthesiology, Huddinge University Hospital (P.S., M.P., J.v.d.L.), and the Division of Medical Engineering, Department of Laboratory Medicine (M.P.), Karolinska Institute, Stockholm, Sweden.

Abstract

Background— The risks that the presence of air microemboli implies in open-heart surgery have recently been emphasized by reports that their number is correlated with the degree of postoperative neuropsychological disorder. Therefore, we studied the effect of CO 2 insufflation into the cardiothoracic wound on the incidence and behavior of microemboli in the heart and ascending aorta. Methods and Results— Twenty patients undergoing single-valve surgery were randomly divided into 2 groups. Ten patients were insufflated with CO 2 via a gas diffuser, and 10 were not. Microemboli were ascertained by intraoperative transesophageal echocardiography (TEE) and recorded on videotape from the moment that the aortic cross-clamp was released until 20 minutes after end of cardiopulmonary bypass (CPB). The surgeon performed standard de-airing maneuvers without being aware of TEE findings. Postoperatively, a blinded assessor determined the maximal number of gas emboli during each consecutive minute in the left atrium, left ventricle, and ascending aorta. The 2 groups did not differ in the usual clinical parameters. The median number of microemboli registered during the whole study period was 161 in the CO 2 group versus 723 in the control group ( P <0.001). Corresponding numbers for the left atrium were 69 versus 340 ( P <0.001), left ventricle 68 versus 254 ( P <0.001), and ascending aorta 56 versus 185 ( P <0.001). In the CO 2 group, the median number of detectable microemboli after CPB fell to zero 7 minutes after CPB versus 19 minutes in the control group ( P <0.001). Conclusions— Insufflation of CO 2 into the thoracic wound markedly decreases the incidence of microemboli.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3