Author:
Roozen Edwin A.,Lomme Roger M. L. M.,Calon Nicole U. B.,ten Broek Richard P. G.,van Goor Harry
Abstract
Abstract
Background
A new hemostatic sealant based on a N-hydroxy-succinimide polyoxazoline (NHS-POx) polymer was evaluated to determine hemostatic efficacy and long-term wound healing and adverse effects in a large animal model of parenchymal organ surgical bleeds.
Methods
Experiment 1 included 20 pigs that were treated with two NHS-POx patch prototypes [a gelatin fibrous carrier (GFC) with NHS-POx and an oxidized regenerated cellulose (ORC) with poly(lactic-co-glycolic acid)-NHS-POx:NU-POx (nucleophilically activated polyoxazoline)], a blank gelatin patch (GFC Blank), TachoSil® and Veriset™ to stop moderate liver and spleen punch bleedings. After various survival periods (1–6 weeks), pigs were re-operated to evaluate patch degradation and parenchymal healing. During the re-operation, experiment 2 was performed: partial liver and spleen resections with severe bleeding, and hemostatic efficacy was evaluated under normal and heparinized conditions of the two previous prototypes and one additional NHS-POx patch. In the third experiment an improved NHS-POx patch (GATT-Patch; GFC-NHS-POx and added 20% as nucleophilically activated polyoxazoline; NU-POx) was compared with TachoSil®, Veriset™ and GFC Blank on punch bleedings and partial liver and spleen resections for rapid (10s) hemostatic efficacy.
Results
NHS-POx-based patches showed better (GFC-NHS-POx 83.1%, ORC-PLGA-NHS-POx: NU-POx 98.3%) hemostatic efficacy compared to TachoSil® (25.0%) and GFC Blank (43.3%), and comparable efficacy with Veriset™ (96.7%) on moderate standardized punch bleedings on liver and spleen. All patches demonstrated gradual degradation over 6 weeks with a reduced local inflammation rate and an improved wound healing. For severe bleedings under non-heparinized conditions, hemostasis was achieved in 100% for Veriset™, 40% for TachoSil and 80–100% for the three NHS-POx prototypes; similar differences between patches remained for heparinized conditions. In experiment 3, GATT-Patch, Veriset™, TachoSil and GFC Blank reached hemostasis after 10s in 100%, 42.8%, 7.1% and 14.3%, respectively, and at 3 min in 100%, 100%, 14.3% and 35.7%, respectively, on all liver and spleen punctures and resections.
Conclusions
NHS-POx-based patches, and particularly the GATT-Patch, are fast in achieving effective hemostatic sealing on standardized moderate and severe bleedings without apparent long-term adverse events.
Publisher
Springer Science and Business Media LLC
Subject
Emergency Medicine,Surgery
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献