End-tidal carbon dioxide tension reflects arterial carbon dioxide tension in the heat-stressed human with and without simulated hemorrhage

Author:

Brothers R. Matthew123,Ganio Matthew S.12,Hubing Kimberly A.1,Hastings Jeffrey L.12,Crandall Craig G.12

Affiliation:

1. Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas;

2. University of Texas Southwestern Medical Center at Dallas, Dallas; and

3. Department of Kinesiology and Health Education, University of Texas at Austin, Austin, Texas

Abstract

End-tidal carbon dioxide tension (PetCO2) is reduced during an orthostatic challenge, during heat stress, and during a combination of these two conditions. The importance of these changes is dependent on PetCO2 being an accurate surrogate for arterial carbon dioxide tension (PaCO2), the latter being the physiologically relevant variable. This study tested the hypothesis that PetCO2 provides an accurate assessment of PaCO2 during the aforementioned conditions. Comparisons between these measures were made: 1) after two levels of heat stress ( N = 11); 2) during combined heat stress and simulated hemorrhage [via lower-body negative pressure (LBNP), N = 8]; and 3) during an end-tidal clamping protocol to attenuate heat stress-induced reductions in PetCO2 ( N = 7). PetCO2 and PaCO2 decreased during heat stress ( P < 0.001); however, there was no group difference between PaCO2 and PetCO2 ( P = 0.36) nor was there a significant interaction between thermal condition and measurement technique ( P = 0.06). To verify that this nonsignificant trend for the interaction was not due to a type II error, PetCO2 and PaCO2 at three distinct thermal conditions were also compared using paired t-tests, revealing no difference between PaCO2 and PetCO2 while normothermic ( P = 0.14) and following a 1.0 ± 0.2°C ( P = 0.21) and 1.4 ± 0.2°C ( P = 0.28) increase in internal temperature. During LBNP while heat stressed, measures of PetCO2 and PaCO2 were similar ( P = 0.61). Likewise, during the end-tidal carbon dioxide clamping protocol, the increases in PetCO2 (7.5 ± 2.8 mmHg) and PaCO2 (6.6 ± 3.4 mmHg) were similar ( P = 0.31). These data indicate that mean PetCO2 reflects mean PaCO2 during the evaluated conditions.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3