Gas exchange and cardiovascular kinetics with different exercise protocols in heart transplant recipients

Author:

Grassi Bruno1,Marconi Claudio1,Meyer Michael1,Rieu Michel1,Cerretelli Paolo1

Affiliation:

1. Section of Physiology, Istituto di Tecnologie Biomediche Avanzate, Consiglio Nazionale delle Ricerche, I-20131 Milan, Italy; Department of Physiology, Max Planck Institut für Experimentelle Medizin, D-37075 Göttingen, Germany; Laboratoire de Physiologie des Adaptations, Université de Paris V, 75014 Paris, France; and Department of Physiology, Centre Médicale Universitaire, Université de Genève, CH-1211 Geneva 4, Switzerland

Abstract

Grassi, Bruno, Claudio Marconi, Michael Meyer, Michel Rieu, and Paolo Cerretelli. Gas exchange and cardiovascular kinetics with different exercise protocols in heart transplant recipients. J. Appl. Physiol. 82(6): 1952–1962, 1997.—Metabolic and cardiovascular adjustments to various submaximal exercises were evaluated in 82 heart transplant recipients (HTR) and in 35 control subjects (C). HTR were tested 21.5 ± 25.3 (SD) mo (range 1.0–137.1 mo) posttransplantation. Three protocols were used: protocol A consisted of 5 min of rectangular 50-W load repeated twice, 5 min apart [5 min rest, 5 min 50 W ( Ex 1), 5 min recovery, 5 min 50 W ( Ex 2)]; protocol B consisted of 5 min of rectangular load at 25, 50, or 75 W; protocol Cconsisted of 15 min of rectangular load at 25 W. Breath-by-breath pulmonary ventilation (V˙e), O2 uptake (V˙o 2), and CO2 output (V˙co 2) were determined. During protocol A, beat-by-beat cardiac output (Q˙) was estimated by impedance cardiography. The half times ( t 1/2) of the on- and off-kinetics of the variables were calculated. In all protocols, t 1/2 values forV˙o 2 on-,V˙e on-, andV˙co 2 on-kinetics were higher (i.e., the kinetics were slower) in HTR than in C, independently of workload and of the time posttransplantation. Also, t 1/2 Q˙ on- was higher in HTR than in C. In protocol A, no significant difference of t 1/2 V˙o 2on- was observed in HTR between Ex 1 (48 ± 9 s) and Ex 2 (46 ± 8 s), whereas t 1/2Q˙ on- was higher during Ex 1 (55 ± 24 s) than during Ex 2 (47 ± 15 s). In all protocols and for all variables, the t 1/2 off-values were higher in HTR than in C. In protocol C, no differences of steady-stateV˙e,V˙o 2, andV˙co 2 were observed in both groups between 5, 10, and 15 min of exercise. We conclude that 1) in HTR, a “priming” exercise, while effective in speeding up the adjustment of convective O2 flow to muscle fibers during a second on-transition, did not affect theV˙o 2 on-kinetics, suggesting that the slower V˙o 2 on- in HTR was attributable to peripheral (muscular) factors; 2) the dissociation between Q˙ on- andV˙o 2 on-kinetics in HTR indicates that an inertia of muscle metabolic machinery is the main factor dictating theV˙o 2on-kinetics; and 3) theV˙o 2 off-kinetics was slower in HTR than in C, indicating a greater alactic O2 deficit in HTR and, therefore, a sluggish muscleV˙o 2 adjustment.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3