Two-photon molecular excitation imaging of Ca2+transients in Langendorff-perfused mouse hearts

Author:

Rubart Michael1,Wang Exing2,Dunn Kenneth W.2,Field Loren J.1

Affiliation:

1. Wells Center for Pediatric Research and Krannert Institute of Cardiology, and

2. Department of Medicine, Division of Nephrology, Indiana University School of Medicine, Indianapolis, Indiana 46202

Abstract

The ability to image calcium signals at subcellular levels within the intact depolarizing heart could provide valuable information toward a more integrated understanding of cardiac function. Accordingly, a system combining two-photon excitation with laser-scanning microscopy was developed to monitor electrically evoked [Ca2+]itransients in individual cardiomyocytes within noncontracting Langendorff-perfused mouse hearts. [Ca2+]itransients were recorded at depths ≤100 μm from the epicardial surface with the fluorescent indicators rhod-2 or fura-2 in the presence of the excitation-contraction uncoupler cytochalasin D. Evoked [Ca2+]i transients were highly synchronized among neighboring cardiomyocytes. At 1 Hz, the times from 90 to 50% ( t 90–50%) and from 50 to 10% ( t 50–10%) of the peak [Ca2+]i were (means ± SE) 73 ± 4 and 126 ± 10 ms, respectively, and at 2 Hz, 62 ± 3 and 94 ± 6 ms ( n = 19, P < 0.05 vs. 1 Hz) in rhod-2-loaded cardiomyocytes. [Ca2+]i decay was markedly slower in fura-2-loaded hearts ( t 90–50% at 1 Hz, 128 ± 9 ms and at 2 Hz, 88 ± 5 ms; t 50–10% at 1 Hz, 214 ± 18 ms and at 2 Hz, 163 ± 7 ms; n = 19, P < 0.05 vs. rhod-2). Fura-2-induced deceleration of [Ca2+]i decline resulted from increased cytosolic Ca2+ buffering, because the kinetics of rhod-2 decay resembled those obtained with fura-2 after incorporation of the Ca2+ chelator BAPTA. Propagating calcium waves and [Ca2+]i amplitude alternans were readily detected in paced hearts. This approach should be of general utility to monitor the consequences of genetic and/or functional heterogeneity in cellular calcium signaling within whole mouse hearts at tissue depths that have been inaccessible to single-photon imaging.

Publisher

American Physiological Society

Subject

Cell Biology,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3