Comparison of the Gibbs and Suga formulations of cardiac energetics: the demise of “isoefficiency”

Author:

Han J.-C.1,Taberner A. J.12,Tran K.1,Goo S.3,Nickerson D. P.1,Nash M. P.12,Nielsen P. M. F.12,Crampin E. J.12,Loiselle D. S.13

Affiliation:

1. Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand;

2. Department of Engineering Science, The University of Auckland, Auckland, New Zealand

3. Department of Physiology, The University of Auckland, Auckland, New Zealand; and

Abstract

Two very different sorts of experiments have characterized the field of cardiac energetics over the past three decades. In one of these, Gibbs and colleagues measured the heat production of isolated papillary muscles undergoing isometric contractions and afterloaded isotonic contractions. The former generated roughly linear heat vs. force relationships. The latter generated enthalpy-load relationships, the peak values of which occurred at or near peak isometric force, i.e., at a relative load of unity. Contractile efficiency showed a pronounced dependence on afterload. By contrast, Suga and coworkers measured the oxygen consumption (V̇o2) while recording the pressure-volume-time work loops of blood-perfused isolated dog hearts. From the associated (linear) end-systolic pressure-volume relations they derived a quantity labeled pressure-volume area (PVA), consisting of the sum of pressure-volume work and unspent elastic energy and showed that this was linearly correlated with V̇o2over a wide range of conditions. This linear dependence imposed isoefficiency: constant contractile efficiency independent of afterload. Neither these data nor those of Gibbs and colleagues are in dispute. Nevertheless, despite numerous attempts over the years, no demonstration of either compatibility or incompatibility of these disparate characterizations of cardiac energetics has been forthcoming. We demonstrate that compatibility between the two formulations is thwarted by the concept of isoefficiency, the thermodynamic basis of which we show to be untenable.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3