Constructing quasi-linear V̇o2 responses from nonlinear parameters

Author:

Wilcox Samuel L.1,Broxterman Ryan M.2ORCID,Barstow Thomas J.1

Affiliation:

1. Department of Kinesiology, Kansas State University, Manhattan, Kansas; and

2. Department of Anatomy and Physiology, Kansas State University, Manhattan, Kansas

Abstract

Oxygen uptake (V̇o2) kinetics have been shown to be governed by a nonlinear control system across a range of work rates. However, the linearity of the V̇o2 response to ramp incremental exercise would appear to be the result of a linear control system. This apparent contradiction could represent a balancing of changing V̇o2 kinetics parameter values across a range of work rates. To test this, six healthy men completed bouts of ramp incremental exercise at 15, 30, and 60 W/min (15R, 30R, 60R, respectively) and four bouts of an extended-step incremental exercise. V̇o2 parameter values were derived from the step exercise using two monoexponential models: one starting at time zero and encompassing the entire stage (MONO), and the other truncated to the first 5 min and allowing a time delay (5TD). The resulting parameter values were applied to an integrative model to estimate the ramp responses. As work rate increased, gain values increased ( P < 0.001 for MONO and 5TD), as did mean response time (or time constant) values (MONO: P < 0.001; 5TD: P = 0.003). Up to maximal V̇o2 (V̇o2 max), the gains of the estimated ramp responses from both models were not different from the gains of the actual observed V̇o2 responses for 15R and 30R (15R: 11.3 ± 1.2, 11.7 ± 0.7, 10.9 ± 0.3; 30R: 10.5 ± 0.8, 11.0 ± 0.5, 10.7 ± 0.3 ml O2·min−1·W−1, for actual, MONO, 5TD, respectively) but were significantly greater for 60R (8.7 ± 1.0, 9.9 ± 0.4, 10.3 ± 0.3 ml O2·min−1·W−1 for actual, MONO, 5TD, respectively). Up to 80%V̇o2 max gain values were not significantly different for any ramp rate ( P > 0.05 for all). We conclude that the apparent linearity of the V̇o2 response to ramp incremental exercise is consequent to a balancing of increasing time constant and gain parameter values.

Funder

National Aeronautics and Space Administration (NASA)

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3