Exposure-response modeling of flow-mediated dilation provides an unbiased and informative measure of endothelial function

Author:

Van Brackle Charles H.1,Harris Ryan A.23,Hallow K. Melissa1ORCID

Affiliation:

1. College of Engineering, University of Georgia, Athens, Georgia;

2. Georgia Prevention Institute, Department of Pediatrics, Augusta University, Augusta, Georgia; and

3. Sport and Exercise Science Research Institute, Ulster University, Jordanstown, Northern Ireland, United Kingdom

Abstract

The brachial artery flow-mediated dilation (FMD) test is the most widely utilized method to evaluate endothelial function noninvasively in humans by calculating the percent change in diameter (FMD%). However, the underutilized velocity and diameter time course data, coupled with confounding influences in shear exposure, noise, and upward bias, make the FMD test less desirable. In this study, we developed an exposure-response, model-based approach that not only quantifies FMD based on the rich velocity and diameter data, it overcomes previously acknowledged challenges. FMD data were obtained from 15 apparently healthy participants, each exposed to four different cuff occlusion durations. The velocity response following cuff release was described by an exponential model with two parameters defining peak velocity and rate of decay. Shear exposure derived from velocity was used to drive the diameter response model, which consists of additive constriction and dilation terms. Three parameters describing distinct aspects of the vascular response to shear (magnitude of the initial constriction response, and magnitude and time constant of the dilation response) were estimated for both the individuals and population. These parameters are independent of shear exposure. Thus this approach produces identifiable and physiologically meaningful parameters that may provide additional information for comparing differences between experimental groups or over time, and provides a means to completely account for shear exposure. NEW & NOTEWORTHY While flow-mediated dilation (FMD) is a valuable tool for evaluating endothelial function, analytical challenges include confounding influences of shear exposure, upward bias, and underutilization of rich time course data collected during FMD testing. We have developed an exposure-response, model-based approach that quantifies endothelial function based on the velocity and diameter data and fully accounts for shear exposure. It produces physiologically meaningful parameters that may provide useful information for comparing differences between experimental groups or over time.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3