Apparatus for measuring rat body volume: a methodological proposition

Author:

Hohl Rodrigo,de Oliveira Renato Buscariolli,Vaz de Macedo Denise,Brenzikofer René

Abstract

We propose a communicating-vessels system to measure body volume in live rats through water level detection by hydrostatic weighing. The reproducibility, accuracy, linearity, and reliability of this apparatus were evaluated in two tests using previously weighed water or six aluminum cylinders of known volume after proper system calibration. The applicability of this apparatus to measurement of live animals (Wistar rats) was tested in a transversal experiment with five rats, anesthetized and nonanesthetized. We took 18 measurements of the volume under each condition (anesthetized and nonanesthetized), totaling 90 measurements. The addition of water volumes (50–700 ml) produced a regression equation with a slope of 1.0006 ± 0.0017, intercept of 0.75 ± 0.81 ( R2= 0.99999, standard error of estimate = 0.58 ml), and bias of ∼1 ml. The differences between cylinders of known volumes and volumes calculated by the system were <0.4 ml. Mean volume errors were 0.01–0.07%. Among the live models, the difference between the volumes obtained for anesthetized and nonanesthetized rats was 0.31 ± 2.34 (SD) ml ( n = 90). These data showed that animal movement does not interfere with the volume measured by the proposed apparatus, and neither anesthesia nor fur shaving is needed for this procedure. Nevertheless, some effort should be taken to eliminate air bubbles trapped in the apparatus or the fur. The proposed apparatus for measuring rat body volume is inexpensive and may be useful for a range of scientific purposes.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Reference31 articles.

1. THE SPECIFIC GRAVITY OF HEALTHY MEN

2. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

3. Untersuchungen zu den Grundlagen des Energie- und Stoffwechsels

4. Braga LR, Mello MAR, Gobatto CA.Exercício contínuo e intermitente: efeitos do treinamento e do destreinamento sobre a gordura corporal de ratos obesos.Arch Latinoam Nutr54: 58–65, 2004.

5. Dawson CA, Horvath SM.Swimming in small laboratory animals.Med Sci Sports2: 51–78, 1970.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3