Load-independent index of diastolic filling: model-based derivation with in vivo validation in control and diastolic dysfunction subjects

Author:

Shmuylovich Leonid,Kovács Sándor J.

Abstract

Maximum elastance is an experimentally validated, load-independent systolic function index stemming from the time-varying elastance paradigm that decoupled extrinsic load from (intrinsic) contractility. Although Doppler echocardiography is the preferred method of diastolic function (DF) assessment, all echo-derived indexes are load dependent, and no invasive or noninvasive load-independent index of filling (LIIF) exists. In this study, we derived and experimentally validated a LIIF. We used a kinematic filling paradigm (the parameterized diastolic filling formalism) to predict and derive the (dimensionless) dynamic diastolic efficiency M, defined by the slope of the peak driving force [maximum driving force ( kx o) ∝ peak atrioventricular (AV) gradient] to maximum viscoelastic resistive force [peak resistive force ( cEpeak)] relation. To validate load independence, we analyzed E-waves recorded while load was varied via tilt table (head up, horizontal, and head down) in 16 healthy volunteers. For the group, linear regression of E-wave derived kx o vs. cEpeak yielded kx o = M ( cEpeak) + B, r2 = 0.98; where M = 1.27 ± 0.09 and B = 5.69 ± 1.70. Effects of diastolic dysfunction (DD) on M were assessed by analysis of preexisting simultaneous cath-echo data in six DD vs. five control subjects. Average M for the DD group ( M = 0.98 ± 0.07) was significantly lower than controls ( M = 1.17 ± 0.05, P < 0.001). We conclude that M is a LIIF because it uncouples intrinsic DF (i.e., the pressure-flow relation) from extrinsic load (left ventricular end-diastolic pressure). Larger M values imply better DF in that increasing AV pressure gradient results in relatively smaller increases in peak resistive losses ( cEpeak). Conversely, lower M implies that increasing AV gradient leads to larger increases in resistive losses. Further prospective validation characterizing M in well-defined pathological states is warranted.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Reference48 articles.

1. THE ECHO-DOPPLER EVALUATION OF LEFT VENTRICULAR DIASTOLIC FUNCTION

2. Bauman L, Chung CS, Karamanoglu M, and Kovács S. The peak atrioventricular pressure gradient to transmitral flow relation: kinematic model prediction with in-vivo validation. J Am Soc Echocardiogr 8: 839–844, 2004.

3. Preload dependence of doppler-derived indexes of left ventricular diastolic function in humans

4. Consequences of Increasing Heart Rate on Deceleration Time, the Velocity–Time Integral, and E/A

5. UNSOLVED PROBLEMS IN DIASTOLE

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com