Estimation of parallel conductance by dual-frequency conductance catheter in mice

Author:

Georgakopoulos Dimitrios1,Kass David A.1

Affiliation:

1. Division of Cardiology, Department of Medicine and Department of Biomedical Engineering, The Johns Hopkins Medical Institutions, Baltimore, Maryland 21287

Abstract

The conductance catheter method has substantially enhanced the characterization of in vivo cardiovascular function in mice. Absolute volume determination requires assessment of parallel conductance ( V p) offset because of conductivity of structures external to the blood pool. Although such a determination is achievable by hypertonic saline bolus injection, this method poses potential risks to mice because of volume loading and/or contractility changes. We tested another method based on differences between blood and muscle conductances at various catheter excitation frequencies (20 vs. 2 kHz) in 33 open-chest mice. The ratio of mean frequency-dependent signal difference to V pderived by hypertonic saline injection was consistent [0.095 ± 0.01 (SD), n = 11], and both methods were strongly correlated ( r 2 = 0.97, P < 0.0001). This correlation persisted when the ratio was prospectively applied to a separate group of animals ( n = 12), with a combined regression relation of V p(DF) = 1.1 ∗ V p(Sal) − 2.5 [where V p(DF) is V p derived by the dual-frequency method and V p(Sal) is V p derived by hypertonic saline bolus injection], r 2 = 0.95, standard error of the estimate = 1.1 μl, and mean difference = 0.6 ± 1.4 μl. Varying V p(Sal) in a given animal resulted in parallel changes in V p(DF) (multiple regression r 2 = 0.92, P < 0.00001). The dominant source of V p in mice was found to be the left ventricular wall itself, since surrounding the heart in the chest with physiological saline or markedly varying right ventricular volumes had a minimal effect on the left ventricular volume signal. On the basis of V p and flow probe-derived cardiac output, end-diastolic volume and ejection fraction in normal mice were 28 ± 3 μl and 81 ± 6%, respectively, at a heart rate of 622 ± 28 min−1. Thus the dual-frequency method and independent flow signal can be used to provide absolute volumes in mice.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 66 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3