Continuous measurement of left ventricular volume in animals and humans by conductance catheter.

Author:

Baan J,van der Velde E T,de Bruin H G,Smeenk G J,Koops J,van Dijk A D,Temmerman D,Senden J,Buis B

Abstract

An eight-electrode conductance catheter previously developed by us and used to determine stroke volume in dogs was applied in human beings and dogs to measure absolute left ventricular volume quantitatively. For calibration we developed the formula V(t) = (1/alpha)(L2/sigma b)G(t) - Vc, where V(t) is time-varying left ventricular volume, alpha is a dimensionless constant, L is the electrode separation, sigma b is the conductivity of blood obtained by a sampling cuvette, and G(t) is the measured conductance within the left ventricular cavity. Vc is a correction term caused by the parallel conductance of structures surrounding the cavity and is measured in two ways. The first method, applicable in the anesthetized animal, consists of temporary reduction of volume to zero by suction. The second method uses a transient change in sigma b by injection of a small bolus of hypertonic saline (dogs) or 10 ml of cold glucose (humans) into the pulmonary artery. The validity of the formula was previously established for the isolated postmortem canine heart. The predicted linearity, slope constant alpha, and accuracy of Vc for the left ventricle in vivo were investigated by comparing the conductance volume data with results from independent methods: electromagnetic blood flow measurement for stroke volume and indicator dilution technique for ejection fraction (dogs), thermal dilution for cardiac output (12 patients), and single-plane cineventriculography for V(t) (five patients). In all comparisons, linear regression showed high correlation (from r = .82 [n = 46] to r = .988 [n = 20]) while alpha, with one exception, ranged from 0.75 to 1.07 and the error in Vc ranged from 0.5% to 16.5% (mean 7%). After positioning of the catheter, no arrhythmias were observed. It is concluded that the conductance catheter provides a reliable and simple method to measure left ventricular volume, giving an on-line, time-varying signal that is easily calibrated. Together with left ventricular pressure obtained through the catheter lumen, the instrument may be used for instantaneous display of pressure-volume loops to facilitate assessment of left ventricular pump performance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 830 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3